Accessoires FC 301/302

Toont 297 product (en)

130B1196

VLT® Modbus TCP MCA 122

MCA 122 Modbus TCP interface Complex compatibility tests make the
perfect operation in Modbus TCP systems for sure.
- On Board web-Page with Drive Status
- Parameterization with MCT10 software
- 2 port version reduces effort for external hardware (switch, cables, etc.) and
allows flexible bus topologies

130B1200

VLT® Profibus DP MCA 101, gecoat

Biedt uitgebreide compatibiliteit, een hoge beschikbaarheid, ondersteuning voor alle toonaangevende PLC-leveranciers en compatibiliteit met toekomstige versies. Snelle, efficiënte communicatie, transparante installatie, geavanceerde diagnostiek en parameterinstelling, en automatische configuratie van procesdata met behulp van een GSD-bestand. Acyclische parameterinstelling met behulp van PROFIBUS DP-V1-, ¬PROFIdrive- of Danfoss FC-profieltoestandsautomaten, PROFIBUS DP-V1, masterklasse 1 en 2.

130B1202

VLT® DeviceNet MCA 104, gecoat

MCA 104 - DeviceNet interface Option for FC300 and FC100
for mounting on the control card. Painted version

130B1203

VLT® Encoder Input MCB 102, gecoat

Biedt de mogelijkheid om verschillende typen incrementele en absolute encoders aan te sluiten. De aangesloten encoder kan worden gebruikt voor snelheidsregeling met terugkoppeling en voor flux-motorregeling met terugkoppeling.

130B1205

VLT® CAN Open MCA 105, gecoat

CANopen interface for FC 300. Max. Baud rate 500 kBit / s. Support that
DSP402 drive profile and PDO / SDO communication. Painted version
for harsh environments. Easy to retrofit thanks to modular technology.

130B1208

VLT® 24 V DC back-up MCB 107, gecoat

Sluit een externe DC-voeding aan om te zorgen dat de stuurkaart en geïnstalleerde opties blijven werken bij een stroomstoring. Maakt volledige werking van het LCP (incl. het instellen van parameters) en alle geïnstalleerde opties mogelijk zonder verbinding met het net.

130B1210

VLT® Relais optie MCB 105, gecoat

Relay extension for FC 100 and FC 300.
Extension with 3 additional load relays (changeover contacts),
easy to retrofit thanks to modular technology.
Painted version for harsh environments,
easy to retrofit thanks to modular technology.
Max. Load 240V AC (resistive): 2 A
Max. Load 240V AC (Cos Phi 0.4): 0.2 A
Max. Load 24V DC (ohmic): 1 A
Max. Load 24V DC (inductive): 0.1 A

130B1220

VLT® Safe PLC I/O MCB 108, gecoat

Increases security and helps you meet requirement security levels
- VLT® AutomationDrive FC 302 has a safety input based on a
single pole 24 V DC input
- Security in a cost-effective way
Possibility of connection to two conductor safety system
Possibility to interrupt on the plus or minus side without disturbing
the sensor signal

130B1227

VLT® Resolver Input MCB 103, gecoat

Resolver extension for FC 300. Enables the connection of the following
Resolver types:
Input voltage: 4..8 Vrms
Input frequency: 2.5..15 kHz
Number of resolver poles: 2 or 4

130B1234

VLT® Motion Control MCO 305, gecoat

Integrated and programmable motion controller for VLT ® AutomationDrive FC 301 and FC 302
- Adds additional functionality and flexibility as it is a freely programmable module
- Optimized for all types of positioning and synchronization applications
- Make your own program specially adapted to your application
Contains:
- synchronization (electronic shaft), positioning and electronic cam control
- 2 inputs support both stepwise and absolute encoders
- 1 encoder output (virtual master function)
10 digital inputs
- 8 digital outputs
- Sends and receives data via fieldbus interface (requires fieldbus option)
- PC software for programming and commissioning
Remember to order the Mounting kit if the above MCO option is required
retrofitted.
130B7530 - Mounting kit for enclosures A2 and A3
130B7531 - Mounting kit for MCO Option,
together with MCB 113, in enclosures A2 and A3
130B1413 - Mounting kit for enclosure B3
130B1414 - Mounting kit for MCO Option,
together with MCB 113, in enclosure B3
130B7532 - Mounting kit for enclosure A5
130B7533 - Mounting kit for all enclosures B, C, D, E and F (B3
excepted)
Danfoss MCO options are not sold without prior advice.
Danfoss can offer help with programming / setting up MCO options.
Contact Danfoss for advice and prices.
Product group: R

130B1235

VLT® PROFINET MCA 120, gecoat

MCA 120 PROFINET interface
With reinforced coating (class 3C3 / IEC 60721-3-3)
-Supports operation on PROFINET network with extensive
characteristics
-DCP support for easy setting u. Communication parameters via the PLC
-on Board web-Page with Drive Status
-parameterization with the MCT10 software
- 2-port version, reduced external hardware

130B1245

VLT® PROFIBUS Converter MCA 113, gecoat

Ensures easy and quick replacement of VLT®3000 to VLT® AutomationDrive
.
VLT® 3000 can then be replaced by VLT® AutomationDrive or
- the system Can be expanded without costly changes to the PLC program
- Flexible investment as it is easy to remove and replace option when upgrading
to another fieldbus
Product group: R1

Weergeven: