Przetwornice niskiego napięcia na Akcesoria

Wyświetlanie 563 produktu/-ów

130B1119

VLT® EtherNet/IP MCA 121, bez pokrycia

MCA 121 EtherNet / IP interface
-Allows connection to EtherNet / IP based Automation systems via CIP (CommonInterface Protocol)
-2 port design reduces external components
-HTTP for diagnosis via built-in web server
-SMTP, DHCP and FTP protocols
-Prepared for parameterization with the MCT 10 software via TCP / IP
-Certified according to ODVA

130B1120

VLT® Safe PLC I/O MCB 108, bez pokrycia

Connection converter for FC 300 with control input for a safe stop. Allows secure connection.
Output modules with diagnostic pulse (Cross-circuit monitoring).

130B1124

VLT® Control Panel LCP 101, numeryczny

Numerical control unit for FC 100 and FC 300. Allows access to all device parameters.
Quick menu for brief commissioning. Manual / auto switchover and alarm acknowledgment.

130B1125

VLT® General Purpose I/O MCB101,bez pokr

MCB 101 - Advanced I / O option
Expands the number of freely programmable Control inputs and outputs around the following I / Os:
- 3 digital inputs opto-decoupled 0 - 24 V.
- 2 analog inputs 0 - 10 V.
- 2 digital outputs NPN / PNP switchable 24 V
- 1 analog output 0/4 - 20 mA

130B1127

VLT® Resolver Input MCB 103,bez pokrycia

Umożliwia podłączenie resolwera w celu zapewnienia sprzężenia zwrotnego prędkości z silnika. Połączenie sprężynowe.

130B1129

Zaślepka zestawu montaż. LCP IP55/66, 8m

IP55/ 66 znajdujący się za panelem LCP, został zamontowany w innym miejscu. Kabel 8 m posiada jeden koniec otwarty; zestaw zawiera również moduł złącz. Brak panelu LCP.
Zestaw obejmuje elementy montażowe, 8 m kabel, uszczelkę i zaślepkę

130B1132

Zestaw adaptacyjny IP 21/Typ 1, A2

Dotyczy to wyłącznie górnej części zestawu. W przypadku zapotrzebowania na zestaw z opcją górną i dolną, należy zamówić 130B1122.

130B1133

Zestaw adaptacyjny IP 21/Typ 1, A3

Dotyczy to wyłącznie górnej części zestawu. W przypadku zapotrzebowania na zestaw z opcją górną i dolną, należy zamówić 130B1123.

130B1134

VLT® Motion Control MCO 305,bez pokrycia

Integrated and programmable motion controller for VLT ® AutomationDrive FC 301 and FC 302
- Adds additional functionality and flexibility as it is a freely programmable module
- Optimized for all types of positioning and synchronization applications
- Make your own program specially adapted to your application
Contains:
- synchronization (electronic shaft), positioning and electronic cam control
- 2 inputs support both stepwise and absolute encoders
- 1 encoder output (virtual master function)
10 digital inputs
8 digital outputs
- Sends and receives data via fieldbus interface (requires fieldbus Option)
- PC software for programming and commissioning.
Remember to order the Mounting kit if the above MCO option is required retrofitted.
130B7530 - Mounting kit for enclosures A2 and A3
130B7531 - Mounting kit for MCO Option, together with MCB 113, in enclosures A2 and A3.
130B1413 - Mounting kit for enclosure B3
130B1414 - Mounting kit for MCO Option, together with MCB 113, in enclosure B3
130B7532 - Mounting kit for enclosure A5
130B7533 - Mounting kit for all enclosures B, C, D, E and F (B3 excepted)
Danfoss MCO options are not sold without prior advice. Danfoss can offer help with
programming / setting up MCO options. Contact Danfoss for advice and prices.
Product group: R

130B1135

VLT® PROFINET MCA 120, bez pokrycia

MCA 120 PROFINET interface
-Supports operation on PROFINET network with extensive properties
-DCP support for easy setting u. Communication parameters via the PLC
- On Board web-Page with Drive Status
- Parameterization with the MCT10 software
- 2 port version, reduced external hardware

130B1137

VLT® PTC Thermistor Card MCB 112, z pokr

MCB 112 PTC - thermistor relay MS220DA In connection with ATEX certified explosion-proof
motors for full motor protection. Certified PTC sensors are the sole protection required.
Integrable module with ATEX-compliant full thermal motor protection
1 PTB-certified PTC thermistor input
1 switch-off signal for using the Safe Stop function
1 logic output for error identification

130B1143

VLT® Analog I/O Option MCB 109, bez pokr

I / O expansion for FC 100, through modular technology easy to retrofit. Analog inputs/outputs
galvanically isolated.
Expands the analog inputs / outputs by:
3 analog inputs: 0 ... 10V / Pt1000 / Ni1000
3 analog outputs: 0 ... 10V
Time switch (RTC backup): lithium cell for 10 years

130B1144

VLT® BACnet MCA 109, bez pokrycia

Open communication protocol dedicated to building automation
- Efficient integration of all parts of building automation equipment
- BACnet: standard for building automation worldwide
- International standard ISO 16484-5
- can be used in all sizes of building automation systems
- the Drive communicates easily with construction management systems running the
BACnet protocol
- can be easily integrated into the network of existing control equipment
Product group: R1

130B1152

VLT® SynchronizingContr. MCO350,bez pokr

Rozbudowuje funkcjonalność przetwornicy VLT® AutomationDrive o synchronizację aplikacji i zastępuje tradycyjne rozwiązania mechaniczne. Synchronizacja prędkości. Synchronizacja pozycji (kąta) z korektą znacznika lub bez niej. Współczynnik przełożenia regulowany na bieżąco. Przesunięcie pozycji (kąta) regulowane na bieżąco. Wyjście enkodera z funkcją wirtualnego mastera napotrzeby synchronizacji wielu urządzeń podrzędnych. Sterowanie przez We/Wy lub magistralę komunikacyjną. Funkcja pozycji wyjściowej. Konfiguracja, a także informacje statusowe i dane są dostępne za pomocą lokalnego panelu sterowania przetwornicy.

130B1153

VLT® Position Controller MCO351,bez pokr

Extends the functional characteristics of the frequency converter in
positioning applications
- Direct positioning via fieldbus, relative positioning, absolute
positioning and touch probe positioning
- End stop handling (software and hardware)
- Mechanical brake handling (programmable hold delay)
Error handling
- Jog speed / manual operation
- None for programming, as it is pre-programmed
Remember to order the Mounting kit if the above MCO option is required retrofitted.
130B7530 - Mounting kit for enclosures A2 and A3
130B7531 - Mounting kit for MCO Option, together with MCB 113, in enclosures A2 and A3
130B1413 - Mounting kit for enclosure B3
130B1414 - Mounting kit for MCO Option, together with MCB 113, in enclosure B3
130B7532 - Mounting kit for enclosure A5
130B7533 - Mounting kit for all enclosures B, C, D, E and F (B3 excepted)
Danfoss MCO options are not sold without prior advice. Danfoss can offer help with
programming / setting up MCO options. Contact Danfoss for advice and prices.
Product group: R

130B1154

VLT® Adv. Cascade Contr. MCO102,bez pokr

Łatwość dopasowania. Rozszerza funkcjonalność wbudowanego sterownika kaskady w celu zapewnienia obsługi do 8 pomp i bardziejzaawansowanego sterowania pompami w trybie master/follower. Obsługuje połączenie wielu pomp o zmiennej i stałej prędkości, atakże konfiguracje z pompami o różnych wydajnościach (mieszane sterowanie). Dodatkowe 7 wejść cyfrowych i połączenie 24 V DCz przetwornicą zapewnia elastyczność dopasowania do zastosowania. Ten sam sprzętowy sterownik kaskady jest kompatybilny z całym zakresem mocy aż do 2 MW.

Widok: