VLT® Advanced Harmonic Filter AHF 005/AHF 010

121 termék látható

AHF-DA-480-400-50-00-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters "VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF010 connected in front of the Danfoss VLT® the harmonic current" distortion generated back to the mains is reduced to maximum 10% at full load.
[!] Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 480A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 00
Cooling concept: Forced cooling is not included within the IP00 design. Cooling must be ensured separately during installation and t
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X8

AHF-DB-034-400-50-00-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3276
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5905
Back plate: 130B3285
Specifications:
THiD less than 5%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 034A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 00
Cooling concept: Cooling must be secured seperately during installation
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X3

AHF-DB-040-400-50-00-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3276
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5905
Back plate: 130B3285
Specifications:
THiD less than 5%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 040A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 00
Cooling concept: Cooling must be secured seperately during installation
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X3

AHF-DB-014-400-50-00-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3274
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5903
Back plate: 130B3283
Specifications:
THiD less than 5%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 014A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 00
Cooling concept: Cooling must be secured seperately during installation
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X1

AHF-DB-010-400-50-00-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3274
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5903
Back plate: 130B3283
Specifications:
THiD less than 5%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 010A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 00
Cooling concept: Cooled by natural convection
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X1