低電壓變頻器 的附件

顯示 508 產品

130B1196

VLT® MODBUS TCP MCA 122

MCA 122 Modbus TCP interface Complex compatibility tests make the
perfect operation in Modbus TCP systems for sure.
- On Board web-Page with Drive Status
- Parameterization with MCT10 software
- 2 port version reduces effort for external hardware (switch, cables, etc.) and
allows flexible bus topologies

130B1200

MCA101 Profibus Option FC-30X-A0 coated

Provides wide compatibility, a high level of availability, support for
all major PLC vendors and compatibility with future versions. Fast,
efficient communication, transparent installation, advanced diagnosis
and parameterization and auto-configuration of process data using GSD-
file. Acyclic parameterization using PROFIBUS DP-V1, ¬PROFIdrive or
Danfoss FC profile state machines, PROFIBUS DP-V1, Master Class 1 and 2.

130B1202

MCA 104 - DeviceNet Option FC300 coated

MCA 104 - DeviceNet interface Option for FC300 and FC100
for mounting on the control card. Painted version

130B1203

VLT® Encoder Input MCB 102, coated

Offers the possibility to connect various types of incremental and
absolute encoders. The connected encoder can be used for closed-loop
speed control as well as closed-loop flux motor control.

130B1205

VLT® CAN Open MCA 105, coated

CANopen interface for FC 300. Max. Baud rate 500 kBit / s. Support that
DSP402 drive profile and PDO / SDO communication. Painted version
for harsh environments. Easy to retrofit thanks to modular technology.

130B1208

1xMCB 107 24V DC coat w. mount. brackets

Connect an external DC supply to keep the control section and any
installed option alive during power failure. Enables full operation of
the LCP (including the parameter setting) and all installed options
without connection to mains.

130B1210

VLT® Relay Option MCB 105, coated

Relay extension for FC 100 and FC 300.
Extension with 3 additional load relays (changeover contacts),
easy to retrofit thanks to modular technology.
Painted version for harsh environments,
easy to retrofit thanks to modular technology.
Max. Load 240V AC (resistive): 2 A
Max. Load 240V AC (Cos Phi 0.4): 0.2 A
Max. Load 24V DC (ohmic): 1 A
Max. Load 24V DC (inductive): 0.1 A

130B1212

VLT® General Purpose I/O MCB 101, ctd

MCB 101 - Advanced I / O option
Expands the number of freely programmable
Control inputs and outputs around the following I / Os:
- 3 digital inputs opto-decoupled 0 - 24 V.
- 2 analog inputs 0 - 10 V.
- 2 digital outputs NPN / PNP switchable 24 V
- 1 analog output 0/4 - 20 mA
with reinforced coating

130B1218

VLT® Ext. Cascade Contr. MCO 101, ctd

Upgrades the built-in cascade controller to control multiple pumps
- easy to mount via plug ‘n’ play
- More advanced pump control in master / follower mode
- Up to 6 pumps in standard cascade control
- Up to 5 pumps in master / follower setup
This MCO option, sits in a B option space.
Danfoss can offer help with programming / setting up MCO options.
Contact Danfoss for advice and prices.
Product group: R

130B1219

VLT® EtherNet IP MCA 121, coated

EtherNet/IP extends commercial off-the-shelf Ethernet to the Common
Industrial Protocol (CIP™) – the same upper-layer protocol and object
model found in DeviceNet. Built-in high-performance switch enabling
line-topology, and eliminating the need for external switches. Device
Level Ring (DLR) topology for higher system availability. Based on CIP™,
makes the reuse of PLC program possible when migrating from DeviceNet to
EtherNet/IP. Built-in web server provides remote diagnosis and reading
out of basic drive parameters. E-mail notification provides fast access
to warnings or alarm information. Unicast and Multicast communication
for improved network utilization. Certified by ODVA for fulfilment of
the newest standard.

130B1220

VLT® Safe PLC I/O MCB 108, coated

Increases security and helps you meet requirement security levels
- VLT® AutomationDrive FC 302 has a safety input based on a
single pole 24 V DC input
- Security in a cost-effective way
Possibility of connection to two conductor safety system
Possibility to interrupt on the plus or minus side without disturbing
the sensor signal

130B1234

MCO 305 SyncPos-Option coated FC300

Integrated and programmable motion controller for VLT ® AutomationDrive FC 301 and FC 302
- Adds additional functionality and flexibility as it is a freely programmable module
- Optimized for all types of positioning and synchronization applications
- Make your own program specially adapted to your application
Contains:
- synchronization (electronic shaft), positioning and electronic cam control
- 2 inputs support both stepwise and absolute encoders
- 1 encoder output (virtual master function)
10 digital inputs
- 8 digital outputs
- Sends and receives data via fieldbus interface (requires fieldbus option)
- PC software for programming and commissioning
Remember to order the Mounting kit if the above MCO option is required
retrofitted.
130B7530 - Mounting kit for enclosures A2 and A3
130B7531 - Mounting kit for MCO Option,
together with MCB 113, in enclosures A2 and A3
130B1413 - Mounting kit for enclosure B3
130B1414 - Mounting kit for MCO Option,
together with MCB 113, in enclosure B3
130B7532 - Mounting kit for enclosure A5
130B7533 - Mounting kit for all enclosures B, C, D, E and F (B3
excepted)
Danfoss MCO options are not sold without prior advice.
Danfoss can offer help with programming / setting up MCO options.
Contact Danfoss for advice and prices.
Product group: R

130B1235

VLT® PROFINET MCA 120, coated

MCA 120 PROFINET interface
With reinforced coating (class 3C3 / IEC 60721-3-3)
-Supports operation on PROFINET network with extensive
characteristics
-DCP support for easy setting u. Communication parameters via the PLC
-on Board web-Page with Drive Status
-parameterization with the MCT10 software
- 2-port version, reduced external hardware

130B1243

VLT® Analog I/O Option MCB 109, coated

I / O extension for FC 100, easy to retrofit thanks to modular technology.
Analog inputs / outputs galvanically isolated.
Expands the analog inputs / outputs by:
3 analog inputs: 0 ... 10V / Pt1000 / Ni1000
3 analog outputs: 0 ... 10V
Time switch (RTC backup): lithium cell for 10 years

130B1244

VLT® BACnet MCA 109, coated

A. Device profile: Application-Specific-Controller (B-ASC)
Supported objects: Analog Input, Analog Output, Analog Value, Binary
Input, binary output,
Binary Value, Device, Multi-State Output, Notification Class
Protocol: Building automation world standard ISO 16484-5
Data Link Layer: MS / TP 9600, 19200, 38400, 76800
Data sharing: ReadProperty-B, DS-RP-B
ReadPropertyMultiple-B, DS-RPM-B
WriteProperty-B, DS-WP-B
WritePropertyMultiple-B, DS-WPM-B
Alarm and Notification Internal-B, AE-N-I-B
Event Notification: ACK-B, AE-ACK-B
Information-B, AE-INFO-B
Device and Network Dynamic Device Binding-A, DM-DDB-A
Management: Dynamic Device Binding-B, DM-DDB-B

130B1245

VLT® PROFIBUS Converter MCA 113, ctd

Ensures easy and quick replacement of VLT®3000 to VLT® AutomationDrive
.
VLT® 3000 can then be replaced by VLT® AutomationDrive or
- the system Can be expanded without costly changes to the PLC program
- Flexible investment as it is easy to remove and replace option when upgrading
to another fieldbus
Product group: R1

檢視: