Lisävarusteet, Pienjännitetaajuusmuuttajat

Näyttää 647 tuotetta

130B1119

VLT® EtherNet/IP MCA 121, päällystämätön

MCA 121 EtherNet / IP interface
-Allows connection to EtherNet / IP based Automation systems via CIP (CommonInterface Protocol)
-2 port design reduces external components
-HTTP for diagnosis via built-in web server
-SMTP, DHCP and FTP protocols
-Prepared for parameterization with the MCT 10 software via TCP / IP
-Certified according to ODVA

130B1120

VLT® Safe PLC I/O MCB 108, ei pääll.

Connection converter for FC 300 with control input for a safe stop. Allows secure connection.
Output modules with diagnostic pulse (Cross-circuit monitoring).

130B1124

VLT® Control Panel LCP 101, numeerinen

Numerical control unit for FC 100 and FC 300. Allows access to all device parameters.
Quick menu for brief commissioning. Manual / auto switchover and alarm acknowledgment.

130B1125

VLT® yleiskäytt. I/O MCB 101, ei pääll.

MCB 101 - Advanced I / O option
Expands the number of freely programmable Control inputs and outputs around the following I / Os:
- 3 digital inputs opto-decoupled 0 - 24 V.
- 2 analog inputs 0 - 10 V.
- 2 digital outputs NPN / PNP switchable 24 V
- 1 analog output 0/4 - 20 mA

130B1127

VLT® Resolver Input MCB 103, ei pääll.

Mahdollistaa resolverin kytkemisen moottorin nopeuden takaisinkytkentätiedon saamiseksi. Jousikuormitteinen liitäntä

130B1129

LCP:n asennussarja, peitek. IP55/66, 8 m

IP55/66, kun LCP on ollut asennettuna muualla. 8 m:n kaapeli on avoin toisesta päästää ja liitinlohko sisältyy pakettiin. Eisisällä LCP:tä.
Sarjaan kuuluvat kiinnikkeet, 8 m:n kaapeli, tiiviste ja peitekansi varmistamiseksi

130B1132

IP 21/Type 1 muunnossarja, yläosa, A2

Tämä on ainoastaan sarjan yläosa – Jos tarvitset sekä ylä- että alaosan sisältävän sarjan, tilaa 130B1122

130B1133

IP 21/Type 1 muunnossarja, yläosa, A3

Tämä on ainoastaan sarjan yläosa – Jos tarvitset sekä ylä- että alaosan sisältävän sarjan, tilaa 130B1123

130B1134

VLT® Motion Control MCO 305, ei pääll.

Integrated and programmable motion controller for VLT ® AutomationDrive FC 301 and FC 302
- Adds additional functionality and flexibility as it is a freely programmable module
- Optimized for all types of positioning and synchronization applications
- Make your own program specially adapted to your application
Contains:
- synchronization (electronic shaft), positioning and electronic cam control
- 2 inputs support both stepwise and absolute encoders
- 1 encoder output (virtual master function)
10 digital inputs
8 digital outputs
- Sends and receives data via fieldbus interface (requires fieldbus Option)
- PC software for programming and commissioning.
Remember to order the Mounting kit if the above MCO option is required retrofitted.
130B7530 - Mounting kit for enclosures A2 and A3
130B7531 - Mounting kit for MCO Option, together with MCB 113, in enclosures A2 and A3.
130B1413 - Mounting kit for enclosure B3
130B1414 - Mounting kit for MCO Option, together with MCB 113, in enclosure B3
130B7532 - Mounting kit for enclosure A5
130B7533 - Mounting kit for all enclosures B, C, D, E and F (B3 excepted)
Danfoss MCO options are not sold without prior advice. Danfoss can offer help with
programming / setting up MCO options. Contact Danfoss for advice and prices.
Product group: R

130B1135

VLT® PROFINET MCA 120, päällystämätön

MCA 120 PROFINET interface
-Supports operation on PROFINET network with extensive properties
-DCP support for easy setting u. Communication parameters via the PLC
- On Board web-Page with Drive Status
- Parameterization with the MCT10 software
- 2 port version, reduced external hardware

130B1137

VLT® PTC Thermistor Card MCB 112,lakattu

MCB 112 PTC - thermistor relay MS220DA In connection with ATEX certified explosion-proof
motors for full motor protection. Certified PTC sensors are the sole protection required.
Integrable module with ATEX-compliant full thermal motor protection
1 PTB-certified PTC thermistor input
1 switch-off signal for using the Safe Stop function
1 logic output for error identification

130B1143

VLT® Analog I/O optio MCB 109, ei pääll.

I / O expansion for FC 100, through modular technology easy to retrofit. Analog inputs/outputs
galvanically isolated.
Expands the analog inputs / outputs by:
3 analog inputs: 0 ... 10V / Pt1000 / Ni1000
3 analog outputs: 0 ... 10V
Time switch (RTC backup): lithium cell for 10 years

130B1144

VLT® BACnet MCA 109, päällystämätön

Open communication protocol dedicated to building automation
- Efficient integration of all parts of building automation equipment
- BACnet: standard for building automation worldwide
- International standard ISO 16484-5
- can be used in all sizes of building automation systems
- the Drive communicates easily with construction management systems running the
BACnet protocol
- can be easily integrated into the network of existing control equipment
Product group: R1

130B1152

VLT® Synchr. Contr. MCO350,ei pääll.

Laajentaa VLT® AutomationDrive -taajuusmuuttajan toiminnallisia ominaisuuksia synkronointisovelluksissa ja korvaa perinteiset mekaaniset ratkaisut. Nopeuden synkronointi. Aseman (kulman) synkronointi merkin korjauksella tai ilman. Suoraan säädettävävälityssuhde. Suoraan säädettävä aseman (kulman) offset. Pulssianturilähtö, jossa on virtuaalinen isäntätoiminto useiden seuraajien synkronointia varten. Ohjaus I/O-liitäntöjen tai kenttäväylän kautta. Paluutoiminto. Konfigurointi sekä tilan ja tietojen lukeminen taajuusmuuttajan paikallisohjauspaneelin kautta.

130B1153

VLT®Position Controller MCO351,ei pääll.

Extends the functional characteristics of the frequency converter in
positioning applications
- Direct positioning via fieldbus, relative positioning, absolute
positioning and touch probe positioning
- End stop handling (software and hardware)
- Mechanical brake handling (programmable hold delay)
Error handling
- Jog speed / manual operation
- None for programming, as it is pre-programmed
Remember to order the Mounting kit if the above MCO option is required retrofitted.
130B7530 - Mounting kit for enclosures A2 and A3
130B7531 - Mounting kit for MCO Option, together with MCB 113, in enclosures A2 and A3
130B1413 - Mounting kit for enclosure B3
130B1414 - Mounting kit for MCO Option, together with MCB 113, in enclosure B3
130B7532 - Mounting kit for enclosure A5
130B7533 - Mounting kit for all enclosures B, C, D, E and F (B3 excepted)
Danfoss MCO options are not sold without prior advice. Danfoss can offer help with
programming / setting up MCO options. Contact Danfoss for advice and prices.
Product group: R

130B1154

VLT® laaj. kaskadiohj. MCO 102, ei pääll

Helppo asentaa. Päivittää sisäänrakennetun kaskadiohjauksen käyttämään jopa kahdeksaa pumppua ja edistyneempää pumpun ohjausta isäntä-/seuraajaohjaustilassa. Tukee useiden vaihtuvanopeuksisten ja vakionopeuspumppujen yhdistelmää sekä kokoonpanoja, joissa on kapasiteetiltaan erilaisia pumppuja (erilaisten pumppujen ohjaus). Seitsemän digitaalista lisätuloa ja 24 V:n tasavirtaliitäntä taajuusmuuttajaan mahdollistaa joustavan sovituksen sovellukseen. Sama kaskadiohjauslaitteisto on yhteensopiva koko tehoalueen kanssa 2 MW:iin asti.

130B1155

USB extension Cable, 350mm

USB-jatkoliitäntä IP55- ja IP66-koteloille.
Siirtää USB-liittimen käytettäväksi taajuusmuuttajan ulkopuolella. USB-jatkoliitäntä on suunniteltu taajuusmuuttajan alaosassa olevaan kaapeliläpivientiin asennettavaksi, jolloin yhteydenpito tietokoneeseen on erittäin helppoa, myös taajuusmuuttajissa, joiden IP-luokitus on korkea.

USB-jatkoliitäntä A5-B1-koteloille

35 cm:n kaapeli

Näytä: