DHW system, TC-DL, 315 kW, DHW controller name: ECL 310, 750 L
004X1621
This product is not available in this store. Please contact your local Customer Service Center.
TC-DL 0750 ECL XB
TC-DL 0750 ECL XB
Gross weight | 230 Kilogram |
Net weight | 230 Kilogram |
EAN | 5715162745083 |
Gross weight | 230 Kilogram |
Net weight | 230 Kilogram |
EAN | 5715162745083 |
Allowed temperature [˚C] [Min] | 2 °C |
Application type | DHW storage & charging |
Approval |
DVGW CE |
Capacity [kW] | 315 kW |
Category name | Antilegionella systems |
CE evaluated | Yes |
China RoHS compliance | Out of scope |
Circulation connection size | G2 3/8" |
Circulation connection type | External thread |
Circulation pipe size | DN50 |
Connection direction primary and secondary | Vertical |
Contain batteries | No |
Current [A] [Max] | 4 A |
DCW static pressure [bar] [Min] | 1 bar |
Delta P primary without heat meter [bar] [Min] | 0.23 bar |
Delta P secondary [bar] [Max] | 0.59 bar |
Depth without cover [mm] | 990 mm |
Description | TC-DL 0750 ECL XB |
Design | Standing |
DH connection size | 48,3/60,3mm |
DH connection type | welded |
DH pipe size | DN40/DN50 |
DHW circulation | Yes |
DHW connection size | G2 3/8" |
DHW connection type | External thread |
DHW Control type | Electronic |
DHW controller name | ECL 310 |
DHW pipe size | DN50 |
DHW pump brand | Grundfos |
DHW pump type | MAGNA3 |
Differential pressure primary [bar] [Max] | 12 bar |
EU RoHS compliance | Out of scope |
Flow circulation [m3/h] [Max] | 6.75 m³/h |
Flow primary [m3/h] [Max] | 9.65 m³/h |
Flow secondary [m3/h] [Max] | 12 m³/h |
HE connection size | 48,3/60,3 mm |
HE connection type | welded |
HE pipe size | DN40/DN50 |
Height without cover [mm] | 2240 mm |
HEX DHW alloy | 1.4404 |
HEX DHW brazed/gasketed material | Brazed copper |
Hot water tank volume [l] | 750 L |
Insulation material | EPS with laminated fleece |
Manufacturer's name | Danfoss |
P circulation [bar] [Max] | -0.23 bar |
Package 2 depth [mm] | 800 mm |
Package 2 height [mm] | 2150 mm |
Package 2 width [mm] | 1200 mm |
Package depth [mm] | 1000 mm |
Package height [mm] | 2290 mm |
Package width [mm] | 1000 mm |
PED category | § 4.3 |
Pressure nominal primary [bar] | 25 bar |
Pressure nominal secondary [bar] | 10 bar |
Pressure primary [bar] [Max] | 25 bar |
Pressure secondary [bar] [Max] | 10 bar |
Product group | DHW system |
REACH Candidate List substances | Lead (CAS no. 7439-92-1) |
Supply temperature construction [˚C] | 90 °C |
Supply voltage [V] AC | 230 V |
Tank material | 1.4571 |
Type | TC-DL |
UL evaluated | Out of scope |
Width without cover [mm] | 2365 mm |
Allowed temperature [˚C] [Min] | 2 °C |
Application type | DHW storage & charging |
Approval |
DVGW CE |
Capacity [kW] | 315 kW |
Category name | Antilegionella systems |
CE evaluated | Yes |
China RoHS compliance | Out of scope |
Circulation connection size | G2 3/8" |
Circulation connection type | External thread |
Circulation pipe size | DN50 |
Connection direction primary and secondary | Vertical |
Contain batteries | No |
Current [A] [Max] | 4 A |
DCW static pressure [bar] [Min] | 1 bar |
Delta P primary without heat meter [bar] [Min] | 0.23 bar |
Delta P secondary [bar] [Max] | 0.59 bar |
Depth without cover [mm] | 990 mm |
Description | TC-DL 0750 ECL XB |
Design | Standing |
DH connection size | 48,3/60,3mm |
DH connection type | welded |
DH pipe size | DN40/DN50 |
DHW circulation | Yes |
DHW connection size | G2 3/8" |
DHW connection type | External thread |
DHW Control type | Electronic |
DHW controller name | ECL 310 |
DHW pipe size | DN50 |
DHW pump brand | Grundfos |
DHW pump type | MAGNA3 |
Differential pressure primary [bar] [Max] | 12 bar |
EU RoHS compliance | Out of scope |
Flow circulation [m3/h] [Max] | 6.75 m³/h |
Flow primary [m3/h] [Max] | 9.65 m³/h |
Flow secondary [m3/h] [Max] | 12 m³/h |
HE connection size | 48,3/60,3 mm |
HE connection type | welded |
HE pipe size | DN40/DN50 |
Height without cover [mm] | 2240 mm |
HEX DHW alloy | 1.4404 |
HEX DHW brazed/gasketed material | Brazed copper |
Hot water tank volume [l] | 750 L |
Insulation material | EPS with laminated fleece |
Manufacturer's name | Danfoss |
P circulation [bar] [Max] | -0.23 bar |
Package 2 depth [mm] | 800 mm |
Package 2 height [mm] | 2150 mm |
Package 2 width [mm] | 1200 mm |
Package depth [mm] | 1000 mm |
Package height [mm] | 2290 mm |
Package width [mm] | 1000 mm |
PED category | § 4.3 |
Pressure nominal primary [bar] | 25 bar |
Pressure nominal secondary [bar] | 10 bar |
Pressure primary [bar] [Max] | 25 bar |
Pressure secondary [bar] [Max] | 10 bar |
Product group | DHW system |
REACH Candidate List substances | Lead (CAS no. 7439-92-1) |
Supply temperature construction [˚C] | 90 °C |
Supply voltage [V] AC | 230 V |
Tank material | 1.4571 |
Type | TC-DL |
UL evaluated | Out of scope |
Width without cover [mm] | 2365 mm |