Ambient temperature range [°C] [max] |
70 °C |
Ambient temperature range [°C] [min] |
-30 °C |
Ambient temperature range [°F] [Max] |
158 °F |
Ambient temperature range [°F] [Min] |
-22 °F |
Approval |
CE CQC EAC LLC CDC TYSK RoHS UKCA UL |
Category |
Art. 3, par. 3 |
CE evaluated |
Yes |
China RoHS compliance |
Yes |
Compatible Danfoss controllers |
EIM 336 EKE 1A EKE 1B EKE 1C |
Connection material |
Copper |
Connection type |
Solder, ODF |
Contain batteries |
No |
Direction |
Angleway |
EU RoHS compliance |
Yes |
EU RoHS exemption clause |
No |
Flow direction |
Bi-flow |
Fluid Group |
2 |
Full travel time speed [s] [Max] |
16 s |
Full travel time speed [s] [Min] |
6 s |
Identical product |
034G5040 |
Inlet size [in] |
5/16 in |
Inlet size [mm] |
7.94 mm |
Lubricants compatibility |
MO POE |
Manual operation option |
AST-G service driver ETS 6 Manual coil |
Max. Working Pressure [bar] |
47 bar |
Max. Working Pressure [psig] |
681 psig |
MaxOPD [bar] |
28 bar |
MaxOPD [psig] |
406 psig |
MOPD[bar/psi] |
28 bar |
Motor type |
Permanent magnet stepper motor |
Orifice size [mm] |
3 mm |
Outlet size [in] |
5/16 in |
Outlet size [mm] |
7.94 mm |
Packing format |
Multi pack |
Parts Program name |
ETS 6 |
Product accessories |
Electric valve accessories |
Product group |
Expansion valves |
Product name |
Electric expansion valve |
Quantity per packing format |
10 pc |
Rated cap. conditions [IMP] |
Subcooling=32 ºF Superheat=32 ºF tcond=100 ºF tevap=41 ºF |
Rated cap. conditions [SI] |
Subcooling=0 ºC Superheat=0 ºC tcond=38 ºC tevap=5 ºC |
Rated capacity R134a [kW] |
20.9 kW |
Rated capacity R134a [TR] |
5.94 TR |
Rated capacity R22 [kW] |
26.8 kW |
Rated capacity R22 [TR] |
7.62 TR |
Rated capacity R404A/R507 [kW] |
18.9 kW |
Rated capacity R404A/R507 [TR] |
5.37 TR |
Rated capacity R407C [kW] |
27.5 kW |
Rated capacity R407C [TR] |
7.82 TR |
Rated capacity R410A [kW] |
31.5 kW |
Rated capacity R410A [TR] |
8.96 TR |
REACH Candidate List substances |
No |
Refrigerant temperature [ºC] [Max] |
70 °C |
Refrigerant temperature [ºC] [Min] |
-30 °C |
Refrigerant temperature [ºF] [Max] |
158 °F |
Refrigerant temperature [ºF] [Min] |
-22 °F |
Refrigerants |
R1234yf R134a R22/R407C R290 R32 R404A/R507A R407H R410A R448A R449A R449B R452A R452B R454A R454B R454C R455A R463A R513A |
Serviceable |
No |
Step mode |
2-phase full step Half step (recommended) Microstep |
Total steps |
480 (half steps) |
Type |
ETS 6 - 30 |
UL approved refrigerants |
R134a R22 R404A R407C R410A R448A R449A R452A R507A |
UL evaluated |
Yes |