130B1100

OPT,CONTROL,PROFIBUS,FC-30X

Provides wide compatibility, a high level of availability, support for
all major PLC vendors and compatibility with future versions. Fast,
efficient communication, transparent installation, advanced diagnosis
and parameterization and auto-configuration of process data using GSD-
file. Acyclic parameterization using PROFIBUS DP-V1, ¬PROFIdrive or
Danfoss FC profile state machines, PROFIBUS DP-V1, Master Class 1 and 2.

130B1102

VLT® DeviceNet MCA 104, uncoated

Robust, efficient data handling thanks to advanced Producer/Consumer
technology. ODVA’s strong conformance testing policies ensure products
are interoperable, and the AC-drive profile, supported using I/O
instance 20/70.21/71, secures compatibility to existing systems.

130B1103

OPTIONS FC CAN OPEN

Standardized handling and interoperability for high flexibility and low
costs. Fully equipped with both high-priority access to control and
status of the drive (PDO Communication) and access to all parameters
through acyclic data (SDO Communication). For interoperability the
option has implemented the DSP402 AC-drive profile.

130B1106

VLT® LonWorks MCA 108, uncoated

Developed for building automation, it enables communication between
individual units in the same system (peer-to-peer) and supports
decentralizing of control. No need for main station (master-follower).
Units receive signals directly. Supports Echelon free-topology interface
(flexible cabling and installation) and embedded I/Os and I/O options
(easy implementation of decentral I/Os). Sensor signals can quickly be
moved to another controller using bus cables. Certified as compliant
with LonMark ver. 3.4 specifications.

130B1107

LCP102 Control Panel for FC100/200/300

Graphic operating unit LCP102 Illuminated graphic display with plain
text. Supports all languages and characters. Quick menu for brief
commissioning.Saving and copying parameter sets.Online help for each
function

130B1108

VLT® 24V DC Supply Option MCB 107

Connect an external DC supply to keep the control section and any
installed option alive during power failure. Enables full operation of
the LCP (including the parameter setting) and all installed options
without connection to mains.

130B1110

MCB105 Relay Option FC300

Relay extension for FC 100 and FC 300. Extension with 3 additional load relays
(changeover contacts), easy to retrofit thanks to modular technology.
Max. Load 240V AC (resistive): 2 A
Max. Load 240V AC (Cos Phi 0.4): 0.2 A
Max. Load 24V DC (ohmic): 1 A
Max. Load 24V DC (inductive): 0.1 A

130B1112

MCF 104 D-Sub 9 Profibus kit

SUB-D9 plug adapter for FC 100 and FC 300. Allows the use of SUB-D9 connectors
at the Profibus DP interface.