Accessories for Low Voltage Drives

Shows 570 product(s)

130B1170

LCP Panel Mounting Kit

The kit includes fasteners and gasket. No LCP and no cable included.

130B1172

VLT® Sensor Input Card MCB 114, unctd

Protects the motor from being overheated by monitoring the temperature
of bearings and windings in the motor. Three self-detecting sensor
inputs for 2 or 3 wire PT100/PT1000 sensors. One additional analog input
4–20 mA.

130B1196

VLT® Modbus TCP MCA 122

MCA 122 Modbus TCP interface Complex compatibility tests make the
perfect operation in Modbus TCP systems for sure.
- On Board web-Page with Drive Status
- Parameterization with MCT10 software
- 2 port version reduces effort for external hardware (switch, cables, etc.) and
allows flexible bus topologies

130B1200

VLT® Profibus DP V1 MCA 101, coated

Provides wide compatibility, a high level of availability, support for
all major PLC vendors and compatibility with future versions. Fast,
efficient communication, transparent installation, advanced diagnosis
and parameterization and auto-configuration of process data using GSD-
file. Acyclic parameterization using PROFIBUS DP-V1, ¬PROFIdrive or
Danfoss FC profile state machines, PROFIBUS DP-V1, Master Class 1 and 2.

130B1202

VLT® DeviceNet MCA 104, coated

MCA 104 - DeviceNet interface Option for FC300 and FC100
for mounting on the control card. Painted version

130B1203

VLT® Encoder Input MCB 102, coated

Offers the possibility to connect various types of incremental and
absolute encoders. The connected encoder can be used for closed-loop
speed control as well as closed-loop flux motor control.

130B1205

VLT® CAN Open MCA 105, coated

CANopen interface for FC 300. Max. Baud rate 500 kBit / s. Support that
DSP402 drive profile and PDO / SDO communication. Painted version
for harsh environments. Easy to retrofit thanks to modular technology.

130B1206

VLT® LonWorks MCA 108, coated

Lonworks interface for FC 100. With modular technology
Fieldbus option that can be easily retrofitted for the decentralized integration
of the Frequency converter. The fieldbus option is based on the LonWorks
Technology and corresponds to the LonMark Interoperability Guide.
Painted version for harsh environments
Hardware: Module technology for option slot A
Transceiver: Free topology FTT 10
Transfer rate: 78kbit / s
Protocol: Echelon LonTalk

130B1208

1xMCB 107 24V DC coat w. mount. brackets

Connect an external DC supply to keep the control section and any
installed option alive during power failure. Enables full operation of
the LCP (including the parameter setting) and all installed options
without connection to mains.

130B1210

VLT® Relay Option MCB 105, coated

Relay extension for FC 100 and FC 300.
Extension with 3 additional load relays (changeover contacts),
easy to retrofit thanks to modular technology.
Painted version for harsh environments,
easy to retrofit thanks to modular technology.
Max. Load 240V AC (resistive): 2 A
Max. Load 240V AC (Cos Phi 0.4): 0.2 A
Max. Load 24V DC (ohmic): 1 A
Max. Load 24V DC (inductive): 0.1 A

130B1212

VLT® General Purpose I/O MCB 101, ctd

MCB 101 - Advanced I / O option
Expands the number of freely programmable
Control inputs and outputs around the following I / Os:
- 3 digital inputs opto-decoupled 0 - 24 V.
- 2 analog inputs 0 - 10 V.
- 2 digital outputs NPN / PNP switchable 24 V
- 1 analog output 0/4 - 20 mA
with reinforced coating

130B1218

VLT® Ext. Cascade Contr. MCO 101, ctd

Upgrades the built-in cascade controller to control multiple pumps
- easy to mount via plug ‘n’ play
- More advanced pump control in master / follower mode
- Up to 6 pumps in standard cascade control
- Up to 5 pumps in master / follower setup
This MCO option, sits in a B option space.
Danfoss can offer help with programming / setting up MCO options.
Contact Danfoss for advice and prices.
Product group: R

View: