Energimätare, SonoSafe 10, 20 mm, null: 2.5, Värme, Batteri 1 A-cell

014U0015

Energy meter for residential applications

Produktinformation

Bruttovikt 0.993 Kilogram
Nettovikt 0.795 Kilogram
Volym 3.142 Liter
EAN 5702425127281

 

1 Primary battery SUM weight Kg 0.018
1 Primary battery weight Kg 0.018
Anslutningsstorlek G 1
Anslutningstyper Gänga
Antal batterier 1
Applikation Värme
Approval authority Force Certification
Approved meteorological range [°C] [Max] 95 °C
Approved meteorological range [°C] [Min] 5 °C
Batteriets livslängd [år] 16 år
Battery type or Name AA Lithium
China RoHS compliance Out of scope
Commissioning tool SonoApp
Description Energy meter for residential applications
Diameter [mm] 20 mm
Difference temperature limits (Accounting) [K] [Max] 90 K
Difference temperature limits (Accounting) [K] [Min] 3 K
Displaytyp LCD
Dynamic range 1:100
EEE category 5 small equipment (any external dimension 50 cm)
Energienhet kWh (utan decimaler efter komma)
EU RoHS compliance Out of scope
Flödesmätningsprincip Ultraljud
Gränssnittsmodul, kortplats 1 No interface module
Husfärg RAL 9010 White
In scope of WEEE Yes
In scope of WEEE and contain batteries Yes
Inbyggd kommunikation M-Bus
Installation Return
IP-klassning IP65
Kabelisoleringsmaterial PVC halogen free
Kabellängd mellan kalkylator och flödesgivare [m] 0.5 m
Kapslingsklass, kalkylator IP65
Kvs-värden [m³/h] 6.25 m³/h
Lagringstemperatur [°C] [Max] 60 °C
Lagringstemperatur [°C] [Min] -25 °C
Log storage duration [Month] 24 mån
Log storage interval [Month] 1 mån
Längd [mm] 130 mm
Material i kontakt med medium Brass sensor
Matningsspänning [V] DC 4 V
Matningsspänningstyp Batteri 1 A-cell
Medietemperatur [°C] [Max] 95 °C
Medietemperatur [°C] [Min] 5 °C
Medium Värmesystem enligt VDI 2035
Noggrannhetsstandard Class 2 to EN1434
Nominellt tryck [bar] 16 bar
Omgivande temperatur [°C] [Max] 55 °C
Omgivande temperatur [°C] [Min] 5 °C
Omgivningsfuktighet [% RH] [Max] 95 %
Omgivningsklass E1 / M2
Produktgrupp Energy meters
qc [m³/h] 0.005 m³/h
qi [m³/h] 0.025 m³/h
qp [m³/h] 2.5 m³/h
qs [m³/h] 5 m³/h
qss [m³/h] 5.5 m³/h
SCIP ID nr c284e070-c802-4ced-837c-2aa2fcd3510f
SCIP-dokumentproduktnamn Ultrasonic Pathfinder
Temperature sensor approved temperature [°C] [Max] 105 °C
Temperature sensor approved temperature [°C] [Min] 0 °C
Temperaturgivare, diameter [mm] 5.2 mm
Temperaturgivare, kabellängd [m] 1.5 m
Temperaturgivartyp Pt 1000
Typ SonoSafe 10
UK RoHS compliance Out of scope
Weight per battery 18 g
ämnen REACHs kandidatlista Lead (CAS no. 7439-92-1)

Tillbehör

Reservdelar

Replacement

Replacement

Replacement

Services

Software

Software and firmware to extend functionality