Visar 296 produkt(er)

130B1102

VLT® DeviceNet MCA 104, uncoated

Robust, efficient data handling thanks to advanced Producer/Consumer
technology. ODVA’s strong conformance testing policies ensure products
are interoperable, and the AC-drive profile, supported using I/O
instance 20/70.21/71, secures compatibility to existing systems.

130B1103

VLT® CAN Open MCA 105, uncoated

Standardized handling and interoperability for high flexibility and low
costs. Fully equipped with both high-priority access to control and
status of the drive (PDO Communication) and access to all parameters
through acyclic data (SDO Communication). For interoperability the
option has implemented the DSP402 AC-drive profile.

130B1107

LCP 102 GRAFISK DISPLAY

Graphic operating unit LCP102 Illuminated graphic display with plain
text. Supports all languages and characters. Quick menu for brief
commissioning.Saving and copying parameter sets.Online help for each
function

130B1108

MCB107 24VDC Supply uncoated for VLT® FC

Connect an external DC supply to keep the control section and any
installed option alive during power failure. Enables full operation of
the LCP (including the parameter setting) and all installed options
without connection to mains.

130B1110

MCB105 Relay Option uncoated for VLT® FC

Relay extension for FC 100 and FC 300. Extension with 3 additional load relays
(changeover contacts), easy to retrofit thanks to modular technology.
Max. Load 240V AC (resistive): 2 A
Max. Load 240V AC (Cos Phi 0.4): 0.2 A
Max. Load 24V DC (ohmic): 1 A
Max. Load 24V DC (inductive): 0.1 A

130B1112

Sub-D9 Adapter kit, A1, A2, A3

SUB-D9 plug adapter for FC 100 and FC 300. Allows the use of SUB-D9 connectors
at the Profibus DP interface.

130B1115

MCB102 Encoder Input VLT® FC300 uncoated

Offers the possibility to connect various types of incremental and
absolute encoders. The connected encoder can be used for closed-loop
speed control as well as closed-loop flux motor control.

130B1117

LCP Mounting Kit, w/ no LCP

The kit includes fasteners, 3m cable and gasket - There is no LCP
included.

130B1119

VLT® EtherNet/IP MCA 121, uncoated

MCA 121 EtherNet / IP interface
-Allows connection to EtherNet / IP based Automation systems via CIP (CommonInterface Protocol)
-2 port design reduces external components
-HTTP for diagnosis via built-in web server
-SMTP, DHCP and FTP protocols
-Prepared for parameterization with the MCT 10 software via TCP / IP
-Certified according to ODVA

130B1120

MCB108 Safty PLC Interface VLT® uncoated

Connection converter for FC 300 with control input for a safe stop. Allows secure connection.
Output modules with diagnostic pulse (Cross-circuit monitoring).

Visa: