VACON® 100 FLOW Enclosed Drive

Shows 659 product(s)

136X8059

70-AB3L03855C10B230BM2H-00128725

Frequency converter
VACON0100-3L-0385-5-ED-FLOW+SEBJ+FL02+DLSE+POCM+GNUL
VACON 100 FLOW
380-500 Vac, 385 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Swedish
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code

Model code: VACON0100-3L-0385-5-ED-FLOW+SEBJ+FL02+DLSE+POCM+GNUL

136X8092

70-AB3L05205C10B230BM2H-00128736

Frequency converter
VACON0100-3L-0520-5-ED-FLOW+SEBJ+FL03+DLNL+FBIE+CIFD+GNUL
VACON 100 FLOW
380-500 Vac, 520 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: Dutch
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code

Model code: VACON0100-3L-0520-5-ED-FLOW+SEBJ+FL03+DLNL+FBIE+CIFD+GNUL

136X8535

70-AB3L03855C10B230BM2H-00128855

Frequency converter
VACON0100-3L-0385-5-ED-FLOW+SBF4+SDE5+SEBJ+FL03+DLNL+CHPH+GNUL
VACON 100 FLOW
380-500 Vac, 385 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: E5,PROFIBUS DP with Sub-D9
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Dutch
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code

Model code: VACON0100-3L-0385-5-ED-FLOW+SBF4+SDE5+SEBJ+FL03+DLNL+CHPH+GNUL

136X9540

70-AB3L05205C10B540BM2H-00129091

Frequency converter
VACON0100-3L-0520-5-ED-FLOW+SEBJ+IP54+EMC4+FL03+DLNL+CIFD+CHPH+CCET000042+EMAN+GNUL
VACON 100 FLOW
380-500 Vac, 520 Amp, IP54/NEMA12
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Dutch
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code

Model code: VACON0100-3L-0520-5-ED-FLOW+SEBJ+IP54+EMC4+FL03+DLNL+CIFD+CHPH+CCET000042+EMAN+GNUL

136X9541

70-AB3L06515C11B540BM2H-00129095

Frequency converter
VACON0100-3L-0651-5-ED-FLOW+SEBJ+IP54+EMC4+FL03+DLNL+CAPT+CAPD+CIFD+CHPH+CCET000042+EMAN+GNUL
VACON 100 FLOW
380-500 Vac, 651 Amp, IP54/NEMA12
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Dutch
MR11
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code

Model code: VACON0100-3L-0651-5-ED-FLOW+SEBJ+IP54+EMC4+FL03+DLNL+CAPT+CAPD+CIFD+CHPH+CCET000042+EMAN+GNUL

136X9583

70-AB3L04605C10B540BM2H-00129107

Frequency converter
VACON0100-3L-0460-5-ED-FLOW+SEBJ+IP54+EMC4+FL03+DLNL+GNUL
VACON 100 FLOW
380-500 Vac, 460 Amp, IP54/NEMA12
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Dutch
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code

Model code: VACON0100-3L-0460-5-ED-FLOW+SEBJ+IP54+EMC4+FL03+DLNL+GNUL

136X9730

70-AB3L03105C09B230BM2H-00128746

Frequency converter
VACON0100-3L-0310-5-ED-FLOW+SCBH+SDE5+SEBJ+FL05+DLDE+CAPT+CAPD+CICO+CIFD+CDLP+CPSB+GNUL
VACON 100 FLOW
380-500 Vac, 310 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: BH,3 temp meas channels
D Slot: E5,PROFIBUS DP with Sub-D9
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: German
Frame 09
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code

Model code: VACON0100-3L-0310-5-ED-FLOW+SCBH+SDE5+SEBJ+FL05+DLDE+CAPT+CAPD+CICO+CIFD+CDLP+CPSB+GNUL

136X9936

70-AB3L02615C09B530BM2H-00129234

Frequency converter
VACON0100-3L-0261-5-ED-FLOW+SCB4+SDBH+SEBJ+SRBT+IP54+FL04+DLPL+CIFD+GNUL
VACON 100 FLOW
380-500 Vac, 261 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: B4,AI,2AO(mA,isol),+24V/EXT
D Slot: BH,3 temp meas channels
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Polish
Frame 09
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code

Model code: VACON0100-3L-0261-5-ED-FLOW+SCB4+SDBH+SEBJ+SRBT+IP54+FL04+DLPL+CIFD+GNUL

136Z0057

70-AB3L03865C09B540BM2H-00129289

Frequency converter
VACON0100-3L-0386-5-ED-FLOW+SBF4+SEBJ+IP54+EMC4+FL02+DLNO+CAPU+CAPD+GNUL
VACON 100 FLOW
380-500 Vac, 386 Amp, IP54/NEMA12
Graphical Keypad MK01
EMC C4 System Component
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Norwegian
Frame 09b
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code

Model code: VACON0100-3L-0386-5-ED-FLOW+SBF4+SEBJ+IP54+EMC4+FL02+DLNO+CAPU+CAPD+GNUL

136Z0246

70-AB3L03855C10B530BM2H-00129366

Frequency converter
VACON0100-3L-0385-5-ED-FLOW+IP54+DLNL+CAPT+CAPD+CAPS+CICO+CIFD+GNUL
VACON 100 FLOW
380-500 Vac, 385 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Dutch
Frame 10
E Slot: No board

Other options according to Model code

Model code: VACON0100-3L-0385-5-ED-FLOW+IP54+DLNL+CAPT+CAPD+CAPS+CICO+CIFD+GNUL

View: