Shows 659 product(s)
70-AB3L03855C10B230BM2H-00127420
Frequency converter
VACON0100-3L-0385-5-ED-FLOW+SEBJ+SRBT+FL04+DLRU+FBIE+CIFD+PODU+GNUL
VACON 100 FLOW
380-500 Vac, 385 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: Russian
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L01705C08B230BM2H-00127091
Frequency converter
VACON0100-3L-0170-5-ED-FLOW+SBF4+SCB4+SDB5+SEBJ+FL05+DLDE+CAPU+CAPD+CICO+CIFD+CPSB+GNUL
VACON 100 FLOW
380-500 Vac, 170 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: B4,AI,2AO(mA,isol),+24V/EXT
D Slot: B5,3RO(NO)
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: German
Frame 08
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L06515C11B230BM2H-00127094
Frequency converter
VACON0100-3L-0651-5-ED-FLOW+SBF4+SCB4+SDB5+SEBJ+FL05+DLDE+CAPU+CAPD+CICO+CIFD+CPSB+GNUL
VACON 100 FLOW
380-500 Vac, 651 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: B4,AI,2AO(mA,isol),+24V/EXT
D Slot: B5,3RO(NO)
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: German
MR11
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L05905C10B530BM2H-00067997
Frequency converter
VACON0100-3L-0590-5-ED-FLOW+SEBJ+IP54+FL03+DLNL+FBIE+CIFD+GNUL
VACON 100 FLOW
380-500 Vac, 590 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: Dutch
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L03105C09B530BM2H-00120038
Frequency converter
VACON0100-3L-0310-5-ED-FLOW+IP54+FBIE+CIFD+GNUL
VACON 100 FLOW
380-500 Vac, 310 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: English
Frame 09
E Slot: No board
Other options according to Model code
70-AB3L02615C09B530BM2H-00126913
Frequency converter
VACON0100-3L-0261-5-ED-FLOW+SBF4+IP54+FL05+DLDE+CAPU+CICO+CIFD+PODU+CPSB+GNUL
VACON 100 FLOW
380-500 Vac, 261 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: German
Frame 09
E Slot: No board
Other options according to Model code
70-AB3L03105C09B230BM2H-00127797
Frequency converter
VACON0100-3L-0310-5-ED-FLOW+SEBJ+FBIE+CIFD+CTID+CHPH+GNUL
VACON 100 FLOW
380-500 Vac, 310 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: English
Frame 09
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L01405C08B530BM2H-00127803
Frequency converter
VACON0100-3L-0140-5-ED-FLOW+IP54+DLDE+COSI+GNUL
VACON 100 FLOW
380-500 Vac, 140 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: German
Frame 08
E Slot: No board
Other options according to Model code
70-AB3L02615C09B230BM2H-00123195
Frequency converter
VACON0100-3L-0261-5-ED-FLOW+SBF4+SDE5+SEBJ+FL05+DLDE+CIFD+GNUL
VACON 100 FLOW
380-500 Vac, 261 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: E5,PROFIBUS DP with Sub-D9
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: German
Frame 09
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L06505C12B230BM2H-00123198
Frequency converter
VACON0100-3L-0650-5-ED-FLOW+SBF4+SDE5+SEBJ+FL05+DLDE+CIFD+GNUL
VACON 100 FLOW
380-500 Vac, 650 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: E5,PROFIBUS DP with Sub-D9
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: German
2xFrame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code