Shows 659 product(s)
70-AB3L05905C10B230BM2H-00119510
Frequency converter
VACON0100-3L-0590-5-ED-FLOW+SEBJ+DNOT+CAPU+CAPD+CIFD+CPS0+GNUL
VACON 100 FLOW
380-500 Vac, 590 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: English
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L10405C12B530BM2H-00119191
VACON0100-3L-1040-5-ED-FLOW+SBF4+SDEC+SEBJ+IP54+FL05+DLDE+CAPU+CAPD+CIFD+PODU+CACH+GNUL
Frequency converter
VACON0100-3L-1040-5-ED-FLOW+SBF4+SDEC+SEBJ+IP54+FL05+DLDE+CAPU+CAPD+CIFD+PODU+CACH+GNUL
VACON 100 FLOW
380-500 Vac, 1040 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: EC,EtherCAT
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: German
2xFrame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L04605C10B530BM2H-00119167
Frequency converter
VACON0100-3L-0460-5-ED-FLOW+SEBJ+IP54+FL02+DLSE+CIFD+POCM+CHCT+GNUL
VACON 100 FLOW
380-500 Vac, 460 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Swedish
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L04605C10B530BM2H-00119630
Frequency converter
VACON0100-3L-0460-5-ED-FLOW+SEBJ+IP54+FL02+DNOT+DLSE+CIFD+POCM+CHCT+GNUL
VACON 100 FLOW
380-500 Vac, 460 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Swedish
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L10405C12B530BM2H-00119635
VACON0100-3L-1040-5-ED-FLOW+SBF4+SDEC+SEBJ+IP54+FL05+DLDE+CIFD+PODU+GNUL
Frequency converter
VACON0100-3L-1040-5-ED-FLOW+SBF4+SDEC+SEBJ+IP54+FL05+DLDE+CIFD+PODU+GNUL
VACON 100 FLOW
380-500 Vac, 1040 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: EC,EtherCAT
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: German
2xFrame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L05905C10B240BM2H-00119769
Frequency converter
VACON0100-3L-0590-5-ED-FLOW+SCBH+SDBH+SEBJ+SRBT+EMC4+DLFR+CAPU+CAPD+CIFD+POCM+CTID+CACL+CPS0+CHIT+GNUL
VACON 100 FLOW
380-500 Vac, 590 Amp, IP21/NEMA1
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: BH,3 temp meas channels
D Slot: BH,3 temp meas channels
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: French
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L05205C10B540BM2H-00119814
VACON0100-3L-0520-5-ED-FLOW+SEBJ+IP54+EMC4+WT03+FL03+DLNL+CIFD+CCET000051+EMAT+GNUL+GADN
Frequency converter
VACON0100-3L-0520-5-ED-FLOW+SEBJ+IP54+EMC4+WT03+FL03+DLNL+CIFD+CCET000051+EMAT+GNUL+GADN
VACON 100 FLOW
380-500 Vac, 520 Amp, IP54/NEMA12
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Dutch
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L05205C10B540BM2H-00119815
VACON0100-3L-0520-5-ED-FLOW+SEBJ+IP54+EMC4+WT03+FL03+DLNL+CIFD+CCET000052+EMAT+GNUL+GAAB
Frequency converter
VACON0100-3L-0520-5-ED-FLOW+SEBJ+IP54+EMC4+WT03+FL03+DLNL+CIFD+CCET000052+EMAT+GNUL+GAAB
VACON 100 FLOW
380-500 Vac, 520 Amp, IP54/NEMA12
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Dutch
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L05205C10B540BM2H-00119816
VACON0100-3L-0520-5-ED-FLOW+SEBJ+IP54+EMC4+WT03+FL03+DLNL+CIFD+CCET000053+GNUL
Frequency converter
VACON0100-3L-0520-5-ED-FLOW+SEBJ+IP54+EMC4+WT03+FL03+DLNL+CIFD+CCET000053+GNUL
VACON 100 FLOW
380-500 Vac, 520 Amp, IP54/NEMA12
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Dutch
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L01705C08B540BM2H-00119853
VACON0100-3L-0170-5-ED-FLOW+SEBJ+IP54+EMC4+WT03+FL03+DLNL+CIFD+CCET000055+GNUL
Frequency converter
VACON0100-3L-0170-5-ED-FLOW+SEBJ+IP54+EMC4+WT03+FL03+DLNL+CIFD+CCET000055+GNUL
VACON 100 FLOW
380-500 Vac, 170 Amp, IP54/NEMA12
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Dutch
Frame 08
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code