Shows 659 product(s)
70-AB3L10405C12B530BM2H-00117170
VACON0100-3L-1040-5-ED-FLOW+SEBJ+SRBT+IP54+FL04+DLPL+FBIE+CIFD+GNUL
Frequency converter
VACON0100-3L-1040-5-ED-FLOW+SEBJ+SRBT+IP54+FL04+DLPL+FBIE+CIFD+GNUL
VACON 100 FLOW
380-500 Vac, 1040 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: Polish
2xFrame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L06507C12B240BM2H-00117459
Frequency converter
VACON0100-3L-0650-7-ED-FLOW+SCB4+SDB5+SEBJ+SRBT+EMC4+FL02+DLSE+CAPT+CAPD+CIFD+POCM+PODU+CPS0+GNUL
VACON 100 FLOW
525-690 Vac, 650 Amp, IP21/NEMA1
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: B4,AI,2AO(mA,isol),+24V/EXT
D Slot: B5,3RO(NO)
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Swedish
2xFrame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L07507C12B240BM2H-00117460
Frequency converter
VACON0100-3L-0750-7-ED-FLOW+SCB4+SDB5+SEBJ+SRBT+EMC4+FL02+DLSE+CAPT+CAPD+CIFD+POCM+PODU+CPS0+GNUL
VACON 100 FLOW
525-690 Vac, 750 Amp, IP21/NEMA1
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: B4,AI,2AO(mA,isol),+24V/EXT
D Slot: B5,3RO(NO)
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Swedish
2xFrame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L05905C10B530BM2H-00117960
VACON0100-3L-0590-5-ED-FLOW+SBF4+SEE5+IP54+DLDE+FBIE+CIFD+POCM+COSI+CHCT+CCET000022+GNUL
Frequency converter
VACON0100-3L-0590-5-ED-FLOW+SBF4+SEE5+IP54+DLDE+FBIE+CIFD+POCM+COSI+CHCT+GNUL
VACON 100 FLOW
380-500 Vac, 590 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: No board
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: German
Frame 10
E Slot: E5,PROFIBUS DP with Sub-D9
Other options according to Model code
70-AB3L06505C12B530BM2H-00117964
VACON0100-3L-0650-5-ED-FLOW+SBF4+SEE5+IP54+DLDE+FBIE+CIFD+POCM+COSI+CHCT+CCET000023+GNUL
Frequency converter
VACON0100-3L-0650-5-ED-FLOW+SBF4+SEE5+IP54+DLDE+FBIE+CIFD+POCM+COSI+CHCT+GNUL
VACON 100 FLOW
380-500 Vac, 650 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: No board
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: German
2xFrame 10
E Slot: E5,PROFIBUS DP with Sub-D9
Other options according to Model code
70-AB3L05905C10B530BM2H-00118072
VACON0100-3L-0590-5-ED-FLOW+SBF4+SEE5+IP54+DLDE+FBIE+CIFD+POCM+COSI+CHCT+GNUL
Frequency converter
VACON0100-3L-0590-5-ED-FLOW+SBF4+SEE5+IP54+DLDE+FBIE+CIFD+POCM+COSI+CHCT+GNUL
VACON 100 FLOW
380-500 Vac, 590 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: No board
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: German
Frame 10
E Slot: E5,PROFIBUS DP with Sub-D9
Other options according to Model code
70-AB3L06505C12B530BM2H-00118079
VACON0100-3L-0650-5-ED-FLOW+SBF4+SEE5+IP54+DLDE+FBIE+CIFD+POCM+COSI+CHCT+GNUL
Frequency converter
VACON0100-3L-0650-5-ED-FLOW+SBF4+SEE5+IP54+DLDE+FBIE+CIFD+POCM+COSI+CHCT+GNUL
VACON 100 FLOW
380-500 Vac, 650 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: No board
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: German
2xFrame 10
E Slot: E5,PROFIBUS DP with Sub-D9
Other options according to Model code
70-AB3L05205C10B540BM2H-00118169
VACON0100-3L-0520-5-ED-FLOW+SEBJ+IP54+EMC4+WT03+FL03+CIFD+EMAT+GNUL+GADN
Frequency converter
VACON0100-3L-0520-5-ED-FLOW+SEBJ+IP54+EMC4+WT03+FL03+CIFD+EMAT+GNUL+GADN
VACON 100 FLOW
380-500 Vac, 520 Amp, IP54/NEMA12
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: English
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L02615C09B540BM2H-00118205
VACON0100-3L-0261-5-ED-FLOW+SEBJ+IP54+EMC4+WT03+FL03+CIFD+CCET000027+EMAT+GNUL+GAAB
Frequency converter
VACON0100-3L-0261-5-ED-FLOW+SEBJ+IP54+EMC4+WT03+FL03+CIFD+EMAT+GNUL+GAAB
VACON 100 FLOW
380-500 Vac, 261 Amp, IP54/NEMA12
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: English
Frame 09
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L03855C10B530BM2H-00118272
Frequency converter
VACON0100-3L-0385-5-ED-FLOW+SEBJ+IP54+DNOT+CAPU+CAPD+CIFD+CACH+CPS0+GNUL
VACON 100 FLOW
380-500 Vac, 385 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: English
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code