Shows 659 product(s)
70-AB3L05907C12B530BM2H-000090750
Frequency converter
VACON0100-3L-0590-7-ED-FLOW+SDE3+SEBJ+IP54+FL05+FBIE+CAPT+CAPD+CIFD+PODU+CTID+CDLP+CPS0+GNUL
VACON 100 FLOW
525-690 Vac, 590 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: E3,PROFIBUS DP
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: English
2xFrame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L03865C09B530BM2H-000090798
Frequency converter
VACON0100-3L-0386-5-ED-FLOW+SCBH+SDE3+SEBJ+IP54+DINS+CAPT+CAPD+CIFD+CDLP+GNUL
VACON 100 FLOW
380-500 Vac, 386 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: BH,3 temp meas channels
D Slot: E3,PROFIBUS DP
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: English
Frame 09b
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L05905C10B240BM2H-000091141
Frequency converter
VACON0100-3L-0590-5-ED-FLOW+SBF4+EMC4+FL05+DLDE+PODU+GNUL
VACON 100 FLOW
380-500 Vac, 590 Amp, IP21/NEMA1
Graphical Keypad MK01
EMC C4 System Component
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: German
Frame 10
E Slot: No board
Other options according to Model code
70-AB3L09205C12B240BM2H-000090718
Frequency converter
VACON0100-3L-0920-5-ED-FLOW+SBF4+EMC4+FL05+DLDE+PODU+GNUL
VACON 100 FLOW
380-500 Vac, 920 Amp, IP21/NEMA1
Graphical Keypad MK01
EMC C4 System Component
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: German
2xFrame 10
E Slot: No board
Other options according to Model code
70-AB3L03105C09B540BM2H-000091692
Frequency converter
VACON0100-3L-0310-5-ED-FLOW+SEBJ+IP54+EMC4+CIFD+CHPH+CCET000042+EMAN+GNUL
VACON 100 FLOW
380-500 Vac, 310 Amp, IP54/NEMA12
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: English
Frame 09
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L11805C12B230BM2H-000092317
Frequency converter
VACON0100-3L-1180-5-ED-FLOW+SEE5+DLFI+GNUL
VACON 100 FLOW
380-500 Vac, 1180 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Finnish
2xFrame 10
E Slot: E5,PROFIBUS DP with Sub-D9
Other options according to Model code
70-AB3L04605C10B230BM2H-000092844
Frequency converter
VACON0100-3L-0460-5-ED-FLOW+SBF4+SEBJ+FL05+DLDE+FBIE+GNUL
VACON 100 FLOW
380-500 Vac, 460 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: No board
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: German
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L04605C10B240BM2H-000093250
Frequency converter
VACON0100-3L-0460-5-ED-FLOW+SEBJ+EMC4+FBIE+CIFD+CTID+GNUL
VACON 100 FLOW
380-500 Vac, 460 Amp, IP21/NEMA1
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: English
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L10405C12B240BM2H-000093254
Frequency converter
VACON0100-3L-1040-5-ED-FLOW+SEBJ+EMC4+FBIE+CIFD+CTID+GNUL
VACON 100 FLOW
380-500 Vac, 1040 Amp, IP21/NEMA1
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: English
2xFrame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L02615C09B240BM2H-000093251
Frequency converter
VACON0100-3L-0261-5-ED-FLOW+SEBJ+EMC4+FBIE+CIFD+CTID+GNUL
VACON 100 FLOW
380-500 Vac, 261 Amp, IP21/NEMA1
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: English
Frame 09
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L04607C12B230BM2H-00081737
Frequency converter
VACON0100-3L-0460-7-ED-FLOW+SDB4+FL04+DLRU+CIFD+PODU+GNUL
VACON 100 FLOW
525-690 Vac, 460 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: B4,AI,2AO(mA,isol),+24V/EXT
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Russian
2xFrame 10
E Slot: No board
Other options according to Model code
70-AB3L04605C10B230BM2H-00075402
Frequency converter
VACON0100-3L-0460-5-ED-FLOW+FL04+DLRU+GNUL
VACON 100 FLOW
380-500 Vac, 460 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Russian
Frame 10
E Slot: No board
Other options according to Model code
70-AB3L05205C10B230BM2H-00104468
Frequency converter
VACON0100-3L-0520-5-ED-FLOW+SEBJ+SRBT+FL04+DLPL+CIFD+POCM+PODU+GNUL
VACON 100 FLOW
380-500 Vac, 520 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Polish
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L04605C10B530BM2H-00104528
Frequency converter
VACON0100-3L-0460-5-ED-FLOW+SBF4+SDE3+SEBJ+IP54+FL02+DLDK+CIFD+PODU+GNUL
VACON 100 FLOW
380-500 Vac, 460 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: E3,PROFIBUS DP
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Danish
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L04167C10B530BM2H-00103776
Frequency converter
VACON0100-3L-0416-7-ED-FLOW+SCB4+SDE3+SEBJ+IP54+FL02+DLDK+CIFD+POCM+PODU+GNUL
VACON 100 FLOW
525-690 Vac, 416 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: B4,AI,2AO(mA,isol),+24V/EXT
D Slot: E3,PROFIBUS DP
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Danish
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L03855C10B230BM2H-00071025
Frequency converter
VACON0100-3L-0385-5-ED-FLOW+FL04+DLRU+GNUL
VACON 100 FLOW
380-500 Vac, 385 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Russian
Frame 10
E Slot: No board
Other options according to Model code
70-AB3L05905C10B530BM2H-00078753
Frequency converter
VACON0100-3L-0590-5-ED-FLOW+SEBJ+IP54+FL03+DLNL+FBIE+GNUL
VACON 100 FLOW
380-500 Vac, 590 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: Dutch
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L05905C10B530BM2H-00093712
Frequency converter
VACON0100-3L-0590-5-ED-FLOW+SCB4+SDB5+SEBJ+IP54+CAPU+CAPD+CICO+CIFD+CACH+CACL+CPS1+CHCB+GNUL
VACON 100 FLOW
380-500 Vac, 590 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: B4,AI,2AO(mA,isol),+24V/EXT
D Slot: B5,3RO(NO)
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: English
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L04605C10B540BM2H-00107801
Frequency converter
VACON0100-3L-0460-5-ED-FLOW+SEBJ+IP54+EMC4+WT03+FL03+DNOT+CIFD+GNUL
VACON 100 FLOW
380-500 Vac, 460 Amp, IP54/NEMA12
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: English
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code
70-AB3L04605C10B540BM2H-00107521
Frequency converter
VACON0100-3L-0460-5-ED-FLOW+SEBJ+IP54+EMC4+WT03+FL03+CIFD+GNUL
VACON 100 FLOW
380-500 Vac, 460 Amp, IP54/NEMA12
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: English
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code