Termix VMTD-F-I FI, Type 1, 16 bar, 120 °C, DHW controller name: IHPT
144B3847
Termix VMTD-F-I-1, insulation with zone valve
Termix VMTD-F-I-1, insulation with zone valve
Gross weight | 18 Kg |
Net weight | 17 Kg |
Volume | 0.037 Cubic.mtr |
Gross weight | 18 Kg |
Net weight | 17 Kg |
Volume | 0.037 Cubic.mtr |
Connection direction | Bottom |
Cover material | White-lacquered steel sheet, White-lacquered In wall. |
Cover option | Extra |
DCW static pressure [bar] [Min] | 1 bar |
Delta P primary without heat meter [bar] [Min] | 0.39 bar |
Depth with cover [mm] | 242 mm |
Depth without cover [mm] | 110 mm |
Description | Termix VMTD-F-I-1, insulation with zone valve |
DH connection size | 3/4" |
DH connection type | G int. Thread |
DH pipe size | Ø18 |
DHW circulation | Extra |
DHW connection size | 3/4" |
DHW connection type | G int. Thread |
DHW Control type | Flow/thermostatic |
DHW controller name | IHPT |
DHW pipe size | Ø18 |
Differential pressure controller | AVPL |
Fitting piece | Energy meter return and cold water meter |
HE connection size | 3/4" |
HE connection type | G int. Thread |
HE pipe size | Ø18 |
Heating control type | Delta p controller + zone valve |
Heating controller name | Zone valve |
Height with cover [mm] | 800 mm |
Height without cover [mm] | 665 mm |
HEX heating brazing material | Copper |
HEX heating type | Brazed |
Insulation material | EPP cover |
Pressure nominal primary [bar] | 16 bar |
Product group | Small Stations |
Station size type | Type 1 |
Supply temperature construction [˚C] | 120 °C |
Supply temperature recommended [˚C] | 100 °C |
Type | Termix VMTD-F-I FI |
Width with cover [mm] | 540 mm |
Width without cover [mm] | 530 mm |
Connection direction | Bottom |
Cover material | White-lacquered steel sheet, White-lacquered In wall. |
Cover option | Extra |
DCW static pressure [bar] [Min] | 1 bar |
Delta P primary without heat meter [bar] [Min] | 0.39 bar |
Depth with cover [mm] | 242 mm |
Depth without cover [mm] | 110 mm |
Description | Termix VMTD-F-I-1, insulation with zone valve |
DH connection size | 3/4" |
DH connection type | G int. Thread |
DH pipe size | Ø18 |
DHW circulation | Extra |
DHW connection size | 3/4" |
DHW connection type | G int. Thread |
DHW Control type | Flow/thermostatic |
DHW controller name | IHPT |
DHW pipe size | Ø18 |
Differential pressure controller | AVPL |
Fitting piece | Energy meter return and cold water meter |
HE connection size | 3/4" |
HE connection type | G int. Thread |
HE pipe size | Ø18 |
Heating control type | Delta p controller + zone valve |
Heating controller name | Zone valve |
Height with cover [mm] | 800 mm |
Height without cover [mm] | 665 mm |
HEX heating brazing material | Copper |
HEX heating type | Brazed |
Insulation material | EPP cover |
Pressure nominal primary [bar] | 16 bar |
Product group | Small Stations |
Station size type | Type 1 |
Supply temperature construction [˚C] | 120 °C |
Supply temperature recommended [˚C] | 100 °C |
Type | Termix VMTD-F-I FI |
Width with cover [mm] | 540 mm |
Width without cover [mm] | 530 mm |