VLT® Advanced Harmonic Filter AHF 005/AHF 010

Viser 172 produkt (er)

130B1751

AHF-DA-436-460-60-20-A

VLT® Advanced Harmonic Filter - AHF 010
The Danfoss Advanced Harmonic Filter is a compact passive harmonic
filter specially designed to match the Danfoss frequency converters
VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC/R Drives.
The program offers two variants, AHF 005 and AHF 010.Connected in
front of the Danfoss VLT® frequency converter, the harmonic current
distortion on the line is reduced to 5% or 10% at nominal load.
Specifications:
Line voltage: 440-480V
Line frequency: 60Hz
Nominal current: 436A
THDi Less than 10%
Cooling concept: Integrated fan with variable speed
Efficiency: > 98 %
Ambient temperature: 5-45 deg C
Enclosure type: X8-V3 IP20 ef
Enclosure degree: IP20 (IP21 / NEMA 1 optional)
Dimensions:
Height: 957mm
Width: 468mm
Depth: 515mm
Accessories:
IP21 / NEMA1 Kit for AHF3 X8 : 175U3282
IP21/NEMA1 Kit for AHF3 X8L with capacitor disconnect option:175U6101
Backplate for AHF X7/X8 : 130B3288

130B1752

AHF-DB-010-460-60-20-A

VLT® Advanced Harmonic Filter -AHF-DB-010-460-60-20-A.
VLT® Advanced Harmonic Filter er avancerede harmoniske filtre, der ikke skal sidestilles med traditionelle harmoniske filtre. De harmoniske filtre fra Danfoss er blevet særligt udviklet til at passe til Danfoss-frekvensomformere. Ved at tilkoble de harmoniske filtre AHF005 foran på en Danfoss-frekvensomformer reduceres den harmoniske strømforvrængning, der er genereret tilbage til netforsyningen, med 5%

Specifikationer:,,
THiD: > 5%
Forsyningsspænding: 440-480V
Frekvens:,,60Hz
Strøm: 010 A
Spændingstolerance: +/- 10%
Frekvenstolerance: +5% / -1,5%
Overbelastningskapacitet: 160% i 60 sek. hvert 10 min.
Kapslingsklasse:,, IP20
Køling: Naturlig køling u. blæser
Effektivitet: > 98%
Omgivelsestemperatur uden derating: 5-45 C°
Dimensioner: 347x190x206 mm
Kapsling:,,X1,,

Tilbehør:,,
IP20 til Type 1/NEMA conversion kit: 130B3274
IP20 til Type 1/NEMA conversion kit med afbryder til kondensator : 130B5903

130B1753

AHF-DB-014-460-60-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3274
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5903
Back plate: 130B3283
Specifications:
THiD less than 5%
Line voltage: 440-480V
Line frequency: 60Hz
Filter current: 014A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X1

130B1754

AHF-DB-019-460-60-20-A

VLT® Advanced Harmonic Filter -AHF-DB-019-460-60-20-A.
VLT® Advanced Harmonic Filter er avancerede harmoniske filtre, der ikke skal sidestilles med traditionelle harmoniske filtre. De harmoniske filtre fra Danfoss er blevet særligt udviklet til at passe til Danfoss-frekvensomformere. Ved at tilkoble de harmoniske filtre AHF005 foran på en Danfoss-frekvensomformer reduceres den harmoniske strømforvrængning, der er genereret tilbage til netforsyningen, med 5%

Specifikationer:,,
THiD: > 5%
Forsyningsspænding: 440-480V
Frekvens:,,60Hz
Strøm: 019 A
Spændingstolerance: +/- 10%
Frekvenstolerance: +5% / -1,5%
Overbelastningskapacitet: 160% i 60 sek. hvert 10 min.
Kapslingsklasse:,, IP20
Køling: Forceret køling med indb. blæser
Effektivitet: > 98%
Omgivelsestemperatur uden derating: 5-45 C°
Dimensioner: 451x230x248 mm
Kapsling:,,X2,,

Tilbehør:,,
IP20 til Type 1/NEMA conversion kit: 130B3275
IP20 til Type 1/NEMA conversion kit med afbryder til kondensator : 130B5904

130B1755

AHF-DB-025-460-60-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3275
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5904
Back plate: 130B3284
Specifications:
THiD less than 5%
Line voltage: 440-480V
Line frequency: 60Hz
Filter current: 025A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X2

Vis: