展示719产品(s)
MCC101A17KT3E00A
Sinus filter for FC 100, FC 200 and FC 300
Degree of protection: IP00
Nominal power (380 - 500V): 5.5 - 7.5 kW
Continuous rated current: 17 A.
Max. Output frequency: 100 Hz
Max. Power loss: 125 W
Dimensions HxWxD: 268 (322) * X 130 X 205 mm
Weight: 7.8 kg
MCC101A75KT3E00A
VLT# MCC101 Sine-wave filter,,
Kapslingsklasse: IP00
Netsp#nding (380 - 500V): 37 kW
Netsp#nding (200 - 240V): 18,5 kW
Nominel str#m: 75 A
Max. Udgangseffekt: 100 Hz
Effekttab ved max belastning: 350 W
Dimensioner HxBxD: 610 (747)* X 170 X 260 mm
V#gt: 50 kg
压力变送器, DST P92S, 0.00 bar - 250.00 bar, 0.00 psi - 3625.00 psi
电气连接: M12 x 1, 压力连接类型: UNF, 压力连接尺寸: 7/16-20, 规格,关键: DST P92S-0250-BAR-R-11-10-01
MCC101A62KT3E20A
Sinus filter FC 100 and FC 300
Degree of protection: IP20
Nominal power (380 - 500V): 30 kW
Nominal power (200 - 240V): 15 kW
Continuous rated current: 62 A.
Max. Output frequency: 100 Hz
Max. Power loss: 310 W
Dimensions HxWxD: 610 (747) * X 170 X 260 mm
Weight: 41 kg
MCC101A8K0T3E00A
Sinus filter for FC 100 and FC 300
Degree of protection: IP00
Nominal power (380 - 500V): 2.2 - 3 kW
Nominal power (200 - 240V): 1.1 - 1.5 kW
Continuous rated current: 8 A.
Max. Output frequency: 120 Hz
Max. Power loss: Dimensions HxWxD: 80 W
Weight: 268 (326) * X 90 X 205 mm
MCC101A10KT3E20A
Sinus filter for FC 100 and FC 300
Degree of protection: IP20
Nominal power (380 - 500V): 4 kW
Nominal power (200 - 240V): 2.2 kW
Continuous rated current: 10 A.
Max. Output frequency: 120 Hz
Max. Power loss: 95 W
Dimensions HxWxD: 268 (325) * X 90 X 205 mm
Weight: 7.1 kg
Antifreeze Thermostat FS20, 0/+15C
TWO-PHASE FROST PROTECTION THERMOSTATS FS-20-UW
Electronic frost protection thermostat or frost monitor with switching
relay output, continuous temperature and valve output (summation output
0–10 V) and control and cascading output (0–10 V), optionally with
connection for a heating element. A IP65 resistant plastic housing with
display with the actual temperature, measuring range,
overrange/underrange of the set switch point (frost protection
temperature) and alarm indicator for "frost" or "error" (capillary
breakage, overvoltage/undervoltage), quick-locking screws and a fully
active sensor rod made of copper. The delivery scope includes a set of
MK-05-K mounting clamps for expert attachment of the sensor rod.
Measuring range: 0...+15 °C / 32...+59 °F
Accuracy: typical ± 1 K (at +10 °C)
Sensor type: 3m Copper rod active along the entire sensor length, min.
response length of 25 cm
Input: 1 x 0 -10 V control input DDC & 1 x 0 -10 V ascading input
Output: 1 x 0 -10 V output temperature (corresponding to 0...+15 °C) &
1 x 0 -10 V output valve (frost signal with control voltage and
cascading)
1 x potential-free changeover contact (24 V), range of adjustment 0...+
15 °C
Current consumption: max. 100 mA at 24 V DC
Load resistance: RL > 50 kOhm
Ambient temperature: –15...+50 °C / 5...+122 °F (Housing) & –20...+60 °C
/ -4...+140 °F Sensor and capillary tube > 20 cm from the housing.
Power: 24VAC/DC (± 10%) 24DC <2,4W
T2-IP65 plastic housing with three-line display 70x40 mm (WxH), a M16
cable glands and MK-05-K mounting clamps.
Housing dimensions: 126 x 90 x 50 mm / 4.96 x 3.54 x 1.97 in