VLT® Advanced Harmonic Filter AHF 005/AHF 010

Показано 172 продуктів

Фільтр AHF-DB-029-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3275
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5904
Back plate: 130B3284
Specifications:
THiD less than 5%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 029A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X2

Фільтр AHF-DB-034-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3276
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5905
Back plate: 130B3285
Specifications:
THiD less than 5%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 034A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X3

Фільтр AHF-DB-040-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3276
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5905
Back plate: 130B3285
Specifications:
THiD less than 5%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 040A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X3

Фільтр AHF-DB-055-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3276
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5905
Back plate: 130B3285
Specifications:
THiD less than 5%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 055A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X3

Фільтр AHF-DB-066-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3277
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5906
Back plate: 130B3286
Specifications:
THiD less than 5%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 066A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X4

Фільтр AHF-DB-082-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3277
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5906
Back plate: 130B3286
Specifications:
THiD less than 5%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 082A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X4

Фільтр AHF-DB-096-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3278
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5907
Back plate: 130B3287
Specifications:
THiD less than 5%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 096A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X5

Фільтр AHF-DB-133-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3278
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5907
Back plate: 130B3287
Specifications:
THiD less than 5%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 133A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X5

Фільтр AHF-DB-171-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3279
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5908
Back plate: 130B3287
Specifications:
THiD less than 5%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 171A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X6

Фільтр AHF-DB-204-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3279
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5908
Back plate: 130B3287
Specifications:
THiD less than 5%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 204A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X6

Вигляд: