Accessories FC 202

Shows 232 product(s)

130B1135

VLT® PROFINET MCA 120, UNCOATED

MCA 120 PROFINET interface
-Supports operation on PROFINET network with extensive properties
-DCP support for easy setting u. Communication parameters via the PLC
- On Board web-Page with Drive Status
- Parameterization with the MCT10 software
- 2 port version, reduced external hardware

130B1137

VLT® PTC Thermistor Card MCB 112, ctd

MCB 112 PTC - thermistor relay MS220DA In connection with ATEX certified explosion-proof
motors for full motor protection. Certified PTC sensors are the sole protection required.
Integrable module with ATEX-compliant full thermal motor protection
1 PTB-certified PTC thermistor input
1 switch-off signal for using the Safe Stop function
1 logic output for error identification

130B1143

VLT® Analog I/O Option MCB 109, unctd

I / O expansion for FC 100, through modular technology easy to retrofit. Analog inputs/outputs
galvanically isolated.
Expands the analog inputs / outputs by:
3 analog inputs: 0 ... 10V / Pt1000 / Ni1000
3 analog outputs: 0 ... 10V
Time switch (RTC backup): lithium cell for 10 years

130B1154

VLT® Adv. Cascade Contr. MCO 102, ctd

Easy to fit. Upgrades built-in cascade controller to operate up to 8
pumps and provide more advanced pump control in master/follower mode.
Supports combination of multiple variable speed and fixed speed pumps,
as well as configurations with pumps of differing capacity (mixed pump
control). The additional 7 digital inputs and the 24-V DC connection to
the drive enable flexible adaptation to the application. The same
cascade controller hardware is compatible with the entire power range up
to 2 MW.

130B1155

USB extension Cable, 350mm

USB extension kit for FC 300 cable length: 350mm for the housing size:
B2, C1 and C2 screw connection M 25

130B1156

USB extension Cable, 650mm

USB extension kit for FC 300 cable length: 650mm for the housing size: B2, C1 and C2
screw connection M 25

130B1164

VLT® Extended Relay Card MCB 113

Adds 7 digital inputs and 2 analog outputs for increased flexibility. 4
SPDT relays. Meets NAMUR recommendations. Galvanic isolation capability.

130B1170

LCP Panel Mounting Kit

The kit includes fasteners and gasket. No LCP and no cable included.

130B1172

VLT® Sensor Input Card MCB 114, unctd

Protects the motor from being overheated by monitoring the temperature
of bearings and windings in the motor. Three self-detecting sensor
inputs for 2 or 3 wire PT100/PT1000 sensors. One additional analog input
4–20 mA.

130B1200

VLT® Profibus DP V1 MCA 101, coated

Provides wide compatibility, a high level of availability, support for
all major PLC vendors and compatibility with future versions. Fast,
efficient communication, transparent installation, advanced diagnosis
and parameterization and auto-configuration of process data using GSD-
file. Acyclic parameterization using PROFIBUS DP-V1, ¬PROFIdrive or
Danfoss FC profile state machines, PROFIBUS DP-V1, Master Class 1 and 2.

130B1202

VLT® DeviceNet MCA 104, coated

MCA 104 - DeviceNet interface Option for FC300 and FC100
for mounting on the control card. Painted version

130B1208

1xMCB 107 24V DC coat w. mount. brackets

Connect an external DC supply to keep the control section and any
installed option alive during power failure. Enables full operation of
the LCP (including the parameter setting) and all installed options
without connection to mains.

130B1210

VLT® Relay Option MCB 105, coated

Relay extension for FC 100 and FC 300.
Extension with 3 additional load relays (changeover contacts),
easy to retrofit thanks to modular technology.
Painted version for harsh environments,
easy to retrofit thanks to modular technology.
Max. Load 240V AC (resistive): 2 A
Max. Load 240V AC (Cos Phi 0.4): 0.2 A
Max. Load 24V DC (ohmic): 1 A
Max. Load 24V DC (inductive): 0.1 A

View: