VLT® Advanced Harmonic Filter AHF 005/AHF 010

Prikazanih proizvoda: 81

AHF-DA-010-400-50-20-A

The Danfoss Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive frequency converters. With AHF 010 connected in front of the Danfoss VLT®, the harmonic current distortion generated back to the mains is reduced to 0.1 total harmonic current distortion at full load.
Accessories:
NEMA 1/IP21 upgrade kit for IP20 units: IP21 / NEMA 1 Kit for AHF X1 enclosure - 130B3274
NEMA 1/IP21 upgrade kit for IP20 units with capacitor disconnect: IP21 / NEMA 1 Kit for AHF X1 enclosure and contactor CI 9 - 130B5903
Back plate: Back plate for X1 - 130B3283

AHF-DA-014-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF 010 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 10% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3274
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5903
Back plate: 130B3283
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 014A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X1

AHF-DA-022-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF 010 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 10% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3275
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5904
Back plate: 130B3284
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 022A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X2

AHF-DA-029-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfo
Enclosure: X2
Ambient temperature without derating: 5-45 ºC
Efficiency: > 98%
Cooling concept: Forced cooled by build-in fan
Enclosure rating: 20
Overload capacity: 160% for 60 sec. every 10 min.
Line frequency tolerances: +5% / -1.5%
Line voltage tolerances: +/- 10%
Filter current: 029A
Line frequency: 50Hz
Line voltage: 380-415V
THiD less than 10%
Specifications:
Back plate: 130B3284
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5904
IP20 to Type 1/NEMA conversion kit: 130B3275
Accessories:uring installation.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately dduced to maximum 10% at full load.ected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is ress frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF 010 conn

AHF-DA-034-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF 010 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 10% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3276
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5905
Back plate: 130B3285
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 034A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X3

Prikaži: