Shows 260 product(s)
VLT® LonWorks MCA 108, coated
Lonworks interface for FC 100. With modular technology
Fieldbus option that can be easily retrofitted for the decentralized integration
of the Frequency converter. The fieldbus option is based on the LonWorks
Technology and corresponds to the LonMark Interoperability Guide.
Painted version for harsh environments
Hardware: Module technology for option slot A
Transceiver: Free topology FTT 10
Transfer rate: 78kbit / s
Protocol: Echelon LonTalk
1xMCB 107 24V DC coat w. mount. brackets
Connect an external DC supply to keep the control section and any
installed option alive during power failure. Enables full operation of
the LCP (including the parameter setting) and all installed options
without connection to mains.
VLT® Relay Option MCB 105, coated
Relay extension for FC 100 and FC 300.
Extension with 3 additional load relays (changeover contacts),
easy to retrofit thanks to modular technology.
Painted version for harsh environments,
easy to retrofit thanks to modular technology.
Max. Load 240V AC (resistive): 2 A
Max. Load 240V AC (Cos Phi 0.4): 0.2 A
Max. Load 24V DC (ohmic): 1 A
Max. Load 24V DC (inductive): 0.1 A
VLT® General Purpose I/O MCB 101, ctd
MCB 101 - Advanced I / O option
Expands the number of freely programmable
Control inputs and outputs around the following I / Os:
- 3 digital inputs opto-decoupled 0 - 24 V.
- 2 analog inputs 0 - 10 V.
- 2 digital outputs NPN / PNP switchable 24 V
- 1 analog output 0/4 - 20 mA
with reinforced coating
VLT® EtherNet IP MCA 121, coated
EtherNet/IP extends commercial off-the-shelf Ethernet to the Common
Industrial Protocol (CIP™) – the same upper-layer protocol and object
model found in DeviceNet. Built-in high-performance switch enabling
line-topology, and eliminating the need for external switches. Device
Level Ring (DLR) topology for higher system availability. Based on CIP™,
makes the reuse of PLC program possible when migrating from DeviceNet to
EtherNet/IP. Built-in web server provides remote diagnosis and reading
out of basic drive parameters. E-mail notification provides fast access
to warnings or alarm information. Unicast and Multicast communication
for improved network utilization. Certified by ODVA for fulfilment of
the newest standard.
VLT® PROFINET MCA 120, coated
MCA 120 PROFINET interface
With reinforced coating (class 3C3 / IEC 60721-3-3)
-Supports operation on PROFINET network with extensive
characteristics
-DCP support for easy setting u. Communication parameters via the PLC
-on Board web-Page with Drive Status
-parameterization with the MCT10 software
- 2-port version, reduced external hardware
VLT® Analog I/O Option MCB 109, coated
I / O extension for FC 100, easy to retrofit thanks to modular technology.
Analog inputs / outputs galvanically isolated.
Expands the analog inputs / outputs by:
3 analog inputs: 0 ... 10V / Pt1000 / Ni1000
3 analog outputs: 0 ... 10V
Time switch (RTC backup): lithium cell for 10 years
VLT® BACnet MCA 109, coated
A. Device profile: Application-Specific-Controller (B-ASC)
Supported objects: Analog Input, Analog Output, Analog Value, Binary
Input, binary output,
Binary Value, Device, Multi-State Output, Notification Class
Protocol: Building automation world standard ISO 16484-5
Data Link Layer: MS / TP 9600, 19200, 38400, 76800
Data sharing: ReadProperty-B, DS-RP-B
ReadPropertyMultiple-B, DS-RPM-B
WriteProperty-B, DS-WP-B
WritePropertyMultiple-B, DS-WPM-B
Alarm and Notification Internal-B, AE-N-I-B
Event Notification: ACK-B, AE-ACK-B
Information-B, AE-INFO-B
Device and Network Dynamic Device Binding-A, DM-DDB-A
Management: Dynamic Device Binding-B, DM-DDB-B
VLT® Modbus TCP MCA 122, coated
The first industrial Ethernet-based protocol for automation. Connects to
Modbus-TCP-based networks. Able to handle connection interval down to 5
ms in both directions, positioning it among the fastest performing
Modbus TCP devices in the market. For master redundancy it features hot
swapping between two masters.