Accessoires voor Laagspanningsregelaars

Toont 818 product (en)

130B1102

VLT® DeviceNet MCA 104, ongecoat

Robuuste, efficiënte gegevensverwerking dankzij het geavanceerde producent/consument-principe. Het krachtige conformiteitstestbeleid van ODVA waarborgt dat producten onderling koppelbaar zijn en het frequentieregelaarprofiel, ondersteund door I/O-instantie 20/70.21/71, garandeert compatibiliteit met bestaande systemen.

130B1103

VLT® CAN Open MCA 105, uncoated

Standardized handling and interoperability for high flexibility and low
costs. Fully equipped with both high-priority access to control and
status of the drive (PDO Communication) and access to all parameters
through acyclic data (SDO Communication). For interoperability the
option has implemented the DSP402 AC-drive profile.

130B1106

VLT® LonWorks MCA 108, uncoated

Developed for building automation, it enables communication between
individual units in the same system (peer-to-peer) and supports
decentralizing of control. No need for main station (master-follower).
Units receive signals directly. Supports Echelon free-topology interface
(flexible cabling and installation) and embedded I/Os and I/O options
(easy implementation of decentral I/Os). Sensor signals can quickly be
moved to another controller using bus cables. Certified as compliant
with LonMark ver. 3.4 specifications.

130B1107

VLT® Control Panel LCP 102

VLT Control Panel LCP 102
Verlicht grafisch display met onopgemaakte tekst.
Biedt ondersteuning voor alle talen en teksttekens.
Snelmenu voor snelle inbedrijfstelling.
Opslag- en kopieerfunctie voor parametersets.
Online help voor alle functies.

130B1108

VLT® 24V DC Supply MCB 107, uncoated

Connect an external DC supply to keep the control section and any
installed option alive during power failure. Enables full operation of
the LCP (including the parameter setting) and all installed options
without connection to mains.

130B1110

VLT® Relais optie MCB 105, ongecoat

Relay extension for FC 100 and FC 300. Extension with 3 additional load relays
(changeover contacts), easy to retrofit thanks to modular technology.
Max. Load 240V AC (resistive): 2 A
Max. Load 240V AC (Cos Phi 0.4): 0.2 A
Max. Load 24V DC (ohmic): 1 A
Max. Load 24V DC (inductive): 0.1 A

130B1112

Sub-D9 adapterset, A1, A2, A3

SUB-D9 plug adapter for FC 100 and FC 300. Allows the use of SUB-D9 connectors
at the Profibus DP interface.

130B1115

VLT® Encoder Input MCB 102, ongecoat

Biedt de mogelijkheid om verschillende typen incrementele en absolute encoders aan te sluiten. De aangesloten encoder kan worden gebruikt voor snelheidsregeling met terugkoppeling en voor flux-motorregeling met terugkoppeling.

130B1119

VLT® EtherNet/IP MCA 121, ongecoat

MCA 121 EtherNet / IP interface
-Allows connection to EtherNet / IP based Automation systems via CIP (CommonInterface Protocol)
-2 port design reduces external components
-HTTP for diagnosis via built-in web server
-SMTP, DHCP and FTP protocols
-Prepared for parameterization with the MCT 10 software via TCP / IP
-Certified according to ODVA

130B1120

VLT® Safe PLC I/O MCB 108, ongecoat

Connection converter for FC 300 with control input for a safe stop. Allows secure connection.
Output modules with diagnostic pulse (Cross-circuit monitoring).