Energy Recovery Device, ISAVE 70

180F7040

Mounting orientation: Vertical, HP out flow [m³/h] [Max]: 70, HP out flow [gpm] [Max]: 308, Rated power [HP]: 30.0, Rated power [kW]: 18.5

Product details

Gross weight 698 Kg
Net weight 614.16 Kg
Volume 1624.104 Liter
EAN 5715162675823

 

Allowable working torque [lbf·ft] [Max] 140 lbf∙ft
Allowable working torque [Nm] [Max] 190 N-m
Ambient temperature [°C] [Max] 50 °C
Ambient temperature [°C] [Min] 0 °C
Ambient temperature [°F] [Max] 122 °F
Ambient temperature [°F] [Min] 32 °F
Base frame STAINLESS
China RoHS compliance Out of scope
Country of origin Denmark
Description iSave70 Vertical IEC200L 18.5kW 6p 50Hz
Differential pressure HP in out [barg] [Max] 5 barg
Differential pressure HP in out [psig] [Max] 72 psig
Drain connection size [in] 1/4 in
Drain connection standard Metric
Drain connection type BSPP
Flow [gpm] [Min] 220 gal/min
Flow [m³/h] [Min] 50 m³/h
HP inlet connection size [in] 3 in
HP Inlet connection standard Victaulic
HP inlet pressure [barg] [Min] 40 barg
HP inlet pressure [psig] [Min] 580 psig
HP inlet pressure, intermittent [barg] [Min] 2 barg
HP inlet pressure, intermittent [psig] [Min] 29 psig
HP out flow [gpm] [Max] 308 gal/min
HP out flow [m³/h] [Max] 70 m³/h
HP outlet connection size [in] 3 in
HP Outlet connection standard Victaulic
HP outlet pressure [barg] [Max] 83 barg
HP outlet pressure [psig] [Max] 1200 psig
In scope of WEEE and contain batteries No
IP protection class IP55
LP in out @ max flow [psig] 11 psig
LP in out @ max. flow [barg] 1 barg
LP in out max. static test pressure [barg] 13 barg
LP in out max. static test pressure [psig] 189 psig
LP inlet allowable working flow [gpm] [Max] 308 gal/min
LP inlet allowable working flow [m³/h] [Max] 70 m³/h
LP Inlet allowable working pressure [barg] [Min] 2 barg
LP Inlet allowable working pressure [psig] [Min] 29 psig
LP inlet connection size [in] 3 in
LP Inlet connection standard Victaulic
LP inlet pressure [barg] [Max] 5 barg
LP inlet pressure [psig] [Max] 72 psig
LP Inlet pressure peak [barg] 10 barg
LP Inlet pressure peak [psig] 145 psig
LP outlet connection size [in] 3 in
Lubrication flow at 60 [m³/h] [Max] 1.5 m³/h
Lubrication flow at 871 [gpm] [Max] 6.6 gal/min
Material type Duplex
Super Duplex
Media temperature [°C] [Max] 35 °C
Media temperature [°C] [Min] 2 °C
Media temperature [°F] [Max] 95 °C
Media temperature [°F] [Min] 36 °C
Motor ambient temperature [°C] [Max] 40 °C
Motor ambient temperature [°F] [Max] 104 °F
Motor current [A] 37 A
Motor frame Size 200L
Motor insulation class B
Motor poles 6
Motor standard IEC
Motor Torque at nom. speed [lbf·ft] 130.5 lbf∙ft
Motor torque at nom. speed [Nm] 177 N-m
Motor voltage 380-420V/660720V, 50 Hz
440-480V, 60 Hz
Mounting orientation Vertical
Outside dimensions of packaging LxWxH [in] 84,3x28,2x40,2
Outside dimensions of packaging LxWxH [mm] 2150x720x1025
Product description iSave
Product Group Energy Recovery Device
Rated power [HP] 30
Rated power [kW] 18.5 kW
REACH Candidate List substances 0.1 No
Seal Material NBR
Serviceable Yes
Sound pressure level [dB(A)] 86 dBA
Speed [rpm] [Max] 875 rpm
Speed [rpm] [Min] 650 rpm
Starting torque [lbf·ft] [Max] 132 lbf∙ft
Starting torque [Nm] [Max] 180 N-m
Static test pressure HP in out [barg] [Max] 108 barg
Static test pressure HP in out [psig] [Max] 1566 psig
Type iSave 50-70
Type designation ISAVE 70
UK RoHS compliance Out of scope

Accessories

Spare Parts

Replacement

Replacement

Replacement

Services

Software

Software and firmware to extend functionality