VACON® 100 FLOW Enclosed Drive

Shows 26 product(s)

132H8240

70-AB3L03865C09B530BM2H-00132947

Frequency converter
VACON0100-3L-0386-5-ED-FLOW+SBF4+IP54+DLFI+CAPT+CAPD+GNUL
VACON 100 FLOW
380-500 Vac, 386 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Finnish
Frame 09b
E Slot: No board

Other options according to Model code

Model code: VACON0100-3L-0386-5-ED-FLOW+SBF4+IP54+DLFI+CAPT+CAPD+GNUL

132H8271

70-AB3L03865C09B230BM2H-00132952

Frequency converter
VACON0100-3L-0386-5-ED-FLOW+SBF4+DLFI+CAPT+CAPD+CIFD+POCM+CHCT+GNUL
VACON 100 FLOW
380-500 Vac, 386 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Finnish
Frame 09b
E Slot: No board

Other options according to Model code

Model code: VACON0100-3L-0386-5-ED-FLOW+SBF4+DLFI+CAPT+CAPD+CIFD+POCM+CHCT+GNUL

132H8416

70-AB3L05905C10B230BM2H-00081205

Frequency converter
VACON0100-3L-0590-5-ED-FLOW+DNOT+GNUL
VACON 100 FLOW
380-500 Vac, 590 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: English
Frame 10
E Slot: No board

Other options according to Model code

Model code: VACON0100-3L-0590-5-ED-FLOW+DNOT+GNUL

132L0802

70-AB3L03855C10B540BM2H-000050957

Frequency converter
VACON0100-3L-0385-5-ED-FLOW+SEBJ+IP54+EMC4+CAPU+CAPD+CIFD+POCM+CACH+EMAR+GNUL+GADN
VACON 100 FLOW
380-500 Vac, 385 Amp, IP54/NEMA12
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: English
Frame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code

Model code: VACON0100-3L-0385-5-ED-FLOW+SEBJ+IP54+EMC4+CAPU+CAPD+CIFD+POCM+CACH+EMAR+GNUL+GADN

132L5364

70-AB3L05205C10B230BM2H-000059462

Frequency converter
VACON0100-3L-0520-5-ED-FLOW+DLFI+CIFD+GNUL
VACON 100 FLOW
380-500 Vac, 520 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Finnish
Frame 10
E Slot: No board

Other options according to Model code

Model code: VACON0100-3L-0520-5-ED-FLOW+DLFI+CIFD+GNUL

132L6336

70-AB3L02617C10B540BM2H-000061254

Frequency converter
VACON0100-3L-0261-7-ED-FLOW+SBF4+IP54+EMC4+CAPU+CAPD+CIFD+POCM+CACH+EMAR+GNUL+GAIN
VACON 100 FLOW
525-690 Vac, 261 Amp, IP54/NEMA12
Graphical Keypad MK01
EMC C4 System Component
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: English
Frame 10
E Slot: No board

Other options according to Model code

Model code: VACON0100-3L-0261-7-ED-FLOW+SBF4+IP54+EMC4+CAPU+CAPD+CIFD+POCM+CACH+EMAR+GNUL+GAIN

132N0136

70-AB3L03865C09B530BM2H-000067207

Frequency converter
VACON0100-3L-0386-5-ED-FLOW+SBF4+IP54+DLFI+FBIE+CAPT+CAPD+CIFD+POCM+CHPH+GNUL
VACON 100 FLOW
380-500 Vac, 386 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: No board
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: Finnish
Frame 09b
E Slot: No board

Other options according to Model code

Model code: VACON0100-3L-0386-5-ED-FLOW+SBF4+IP54+DLFI+FBIE+CAPT+CAPD+CIFD+POCM+CHPH+GNUL

132N0751

70-AB3L07305C12B230BM2H-000068295

Frequency converter
VACON0100-3L-0730-5-ED-FLOW+SBF4+SCBH+SDBH+SEE5+DLFI+CAPT+CAPD+CIFD+POCM+GNUL
VACON 100 FLOW
380-500 Vac, 730 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: BH,3 temp meas channels
D Slot: BH,3 temp meas channels
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Finnish
2xFrame 10
E Slot: E5,PROFIBUS DP with Sub-D9

Other options according to Model code

Model code: VACON0100-3L-0730-5-ED-FLOW+SBF4+SCBH+SDBH+SEE5+DLFI+CAPT+CAPD+CIFD+POCM+GNUL

132N3748

70-AB3L04605C10B530BM2H-000073111

Frequency converter
VACON0100-3L-0460-5-ED-FLOW+SDE9+IP54+DLFI+CAPU+CAPD+CIFD+POCM+CACH+GNUL
VACON 100 FLOW
380-500 Vac, 460 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: E9,2-port ethernet
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Finnish
Frame 10
E Slot: No board

Other options according to Model code

Model code: VACON0100-3L-0460-5-ED-FLOW+SDE9+IP54+DLFI+CAPU+CAPD+CIFD+POCM+CACH+GNUL

132N4247

70-AB3L01405C08B530BM2H-000073376

Frequency converter
VACON0100-3L-0140-5-ED-FLOW+SCB2+SDEA+SEBJ+IP54+DLFI+FBIE+GNUL
VACON 100 FLOW
380-500 Vac, 140 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: B2,1RO(NO/NC),1RO(NO),therm
D Slot: EA,Advanced 2-port ethernet
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: Finnish
Frame 08
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code

Model code: VACON0100-3L-0140-5-ED-FLOW+SCB2+SDEA+SEBJ+IP54+DLFI+FBIE+GNUL

132N4248

70-AB3L02615C09B530BM2H-000073374

Frequency converter
VACON0100-3L-0261-5-ED-FLOW+SCB2+SDEA+SEBJ+IP54+DLFI+FBIE+GNUL
VACON 100 FLOW
380-500 Vac, 261 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: B2,1RO(NO/NC),1RO(NO),therm
D Slot: EA,Advanced 2-port ethernet
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: Finnish
Frame 09
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code

Model code: VACON0100-3L-0261-5-ED-FLOW+SCB2+SDEA+SEBJ+IP54+DLFI+FBIE+GNUL

132N5352

70-AB3L02627C09B540BM2H-000075081

Frequency converter
VACON0100-3L-0262-7-ED-FLOW+SCB2+SDB4+IP54+EMC4+CAPU+CAPD+CIFD+POCM+CACH+EMAR+GNUL+GADN
VACON 100 FLOW
525-690 Vac, 262 Amp, IP54/NEMA12
Graphical Keypad MK01
EMC C4 System Component
B Slot: F3,3 Relay board
C Slot: B2,1RO(NO/NC),1RO(NO),therm
D Slot: B4,AI,2AO(mA,isol),+24V/EXT
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: English
Frame 09b
E Slot: No board

Other options according to Model code

Model code: VACON0100-3L-0262-7-ED-FLOW+SCB2+SDB4+IP54+EMC4+CAPU+CAPD+CIFD+POCM+CACH+EMAR+GNUL+GADN

132N5636

70-AB3L02087C09B230BM2H-000075317

Frequency converter
VACON0100-3L-0208-7-ED-FLOW+SCBH+SDE5+SEBJ+DLFI+CIFD+PODU+GNUL
VACON 100 FLOW
525-690 Vac, 208 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: BH,3 temp meas channels
D Slot: E5,PROFIBUS DP with Sub-D9
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Finnish
Frame 09
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code

Model code: VACON0100-3L-0208-7-ED-FLOW+SCBH+SDE5+SEBJ+DLFI+CIFD+PODU+GNUL

132X6075

70-AB3L02627C09B230BM2H-000089037

Frequency converter
VACON0100-3L-0262-7-ED-FLOW+SCBH+DLFI+FBIE+CAPT+CAPD+CIFD+PODU+CHPH+GNUL
VACON 100 FLOW
525-690 Vac, 262 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: BH,3 temp meas channels
D Slot: No board
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: Finnish
Frame 09b
E Slot: No board

Other options according to Model code

Model code: VACON0100-3L-0262-7-ED-FLOW+SCBH+DLFI+FBIE+CAPT+CAPD+CIFD+PODU+CHPH+GNUL

132X6888

70-AB3L05905C10B530BM2H-000087389

Frequency converter
VACON0100-3L-0590-5-ED-FLOW+SBF4+IP54+DLFI+CIFD+POCM+CHCT+GNUL
VACON 100 FLOW
380-500 Vac, 590 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Finnish
Frame 10
E Slot: No board

Other options according to Model code

Model code: VACON0100-3L-0590-5-ED-FLOW+SBF4+IP54+DLFI+CIFD+POCM+CHCT+GNUL

132X7437

70-AB3L05907C12B530BM2H-000090750

Frequency converter
VACON0100-3L-0590-7-ED-FLOW+SDE3+SEBJ+IP54+FL05+FBIE+CAPT+CAPD+CIFD+PODU+CTID+CDLP+CPS0+GNUL
VACON 100 FLOW
525-690 Vac, 590 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: E3,PROFIBUS DP
Fieldbus: IndEth (ProfinetIO,EthernetIP)
Manual: English
2xFrame 10
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code

Model code: VACON0100-3L-0590-7-ED-FLOW+SDE3+SEBJ+IP54+FL05+FBIE+CAPT+CAPD+CIFD+PODU+CTID+CDLP+CPS0+GNUL

132X7506

70-AB3L03865C09B530BM2H-000090798

Frequency converter
VACON0100-3L-0386-5-ED-FLOW+SCBH+SDE3+SEBJ+IP54+DINS+CAPT+CAPD+CIFD+CDLP+GNUL
VACON 100 FLOW
380-500 Vac, 386 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: BH,3 temp meas channels
D Slot: E3,PROFIBUS DP
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: English
Frame 09b
E Slot: BJ,STO, ATEX therm
ATEX: II (2) GD
Other options according to Model code

Model code: VACON0100-3L-0386-5-ED-FLOW+SCBH+SDE3+SEBJ+IP54+DINS+CAPT+CAPD+CIFD+CDLP+GNUL

132X8615

70-AB3L11805C12B230BM2H-000092317

Frequency converter
VACON0100-3L-1180-5-ED-FLOW+SEE5+DLFI+GNUL
VACON 100 FLOW
380-500 Vac, 1180 Amp, IP21/NEMA1
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F3,3 Relay board
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Finnish
2xFrame 10
E Slot: E5,PROFIBUS DP with Sub-D9

Other options according to Model code

Model code: VACON0100-3L-1180-5-ED-FLOW+SEE5+DLFI+GNUL

136Z1987

70-AB3L02617C10B540BM2H-00106579

Frequency converter
VACON0100-3L-0261-7-ED-FLOW+SBF4+IP54+EMC4+WT04+CAPU+CAPD+CIFD+POCM+CACH+EMAR+GNUL+GAIN
VACON 100 FLOW
525-690 Vac, 261 Amp, IP54/NEMA12
Graphical Keypad MK01
EMC C4 System Component
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: English
Frame 10
E Slot: No board

Other options according to Model code

Model code: VACON0100-3L-0261-7-ED-FLOW+SBF4+IP54+EMC4+WT04+CAPU+CAPD+CIFD+POCM+CACH+EMAR+GNUL+GAIN

136Z6984

70-AB3L03855C10B530BM2H-00117100

Frequency converter
VACON0100-3L-0385-5-ED-FLOW+SBF4+IP54+DLFI+POCM+GNUL
VACON 100 FLOW
380-500 Vac, 385 Amp, IP54/NEMA12
Graphical Keypad MK01
C3 Commercial&Industry Environ
B Slot: F4,2 Relay board with therm
C Slot: No board
D Slot: No board
Fieldbus: Std protocol,Modbus,N2,BacNet
Manual: Finnish
Frame 10
E Slot: No board

Other options according to Model code

Model code: VACON0100-3L-0385-5-ED-FLOW+SBF4+IP54+DLFI+POCM+GNUL

View: