VLT® Line Reactor MCC 103

Mostrar 19 productos

MCC103A44K0T5L1670E00TB

frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive in applications using load sharing. Use the MCC 103 line reactor for up to 500V mains supply with 50 Hz or 60 Hz mains frequency. The MCC 103 line reactor is available with IP00 enclosure protection.
Mounting,,: Vertical or horizontal
Enclosure degree: IP00
Dimensions - HxWxD: 195x155 x102 mm
Weight: 3.8 kg
Operating conditions: Permanent operation with 100% load
Type of cooling: Cooled by natural convection
Derating > 1km: 5%/1km
Derating > 45 °C: 2.5%/K
Ambient temperature without derating: -10 to +45 C°
PE connection - dimension: M5x10
PE connection - type: Screw connection
Mains connection - tightening torque: 4.0-5.0 Nm
Mains connection - dimension: 35 mm2
Mains connection - type: Screw terminal
L tolerance: ±10%
Winding resistance: 5.4 mOhm
Inductance L: 167 uH
Rated current,,44 A
Rated frequency: 50-60 Hz
Rated voltage:,,380-500 V
Specifications:,,

MCC 103 line reactor is specially designed to match the Danfoss

VLT® Line reactor MCC 103 - line reactor for load sharing

MCC103A25K0T5L3200E00TB

frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive in applications using load sharing. Use the MCC 103 line reactor for up to 500V mains supply with 50 Hz or 60 Hz mains frequency. The MCC 103 line reactor is available with IP00 enclosure protection.
Mounting,,: Vertical or horizontal
Enclosure degree: IP00
Dimensions - HxWxD: 150x120 x90 mm
Weight: 1.9 kg
Operating conditions: Permanent operation with 100% load
Type of cooling: Cooled by natural convection
Derating > 1km: 5%/1km
Derating > 45 °C: 2.5%/K
Ambient temperature without derating: -10 to +45 C°
PE connection - dimension: M5x10
PE connection - type: Screw connection
Mains connection - tightening torque: 1.5-2.5 Nm
Mains connection - dimension: 16 mm2
Mains connection - type: Screw terminal
L tolerance: ±10%
Winding resistance: 16 mOhm
Inductance L: 320 uH
Rated current,,25 A
Rated frequency: 50-60 Hz
Rated voltage:,,380-500 V
Specifications:,,

MCC 103 line reactor is specially designed to match the Danfoss

VLT® Line reactor MCC 103 - line reactor for load sharing

MCC103A7K00T5L1051E00TB

frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive in applications using load sharing. Use the MCC 103 line reactor for up to 500V mains supply with 50 Hz or 60 Hz mains frequency. The MCC 103 line reactor is available with IP00 enclosure protection.
Mounting,,: Vertical or horizontal
Enclosure degree: IP00
Dimensions - HxWxD: 102x78 x63 mm
Weight: 0.85 kg
Operating conditions: Permanent operation with 100% load
Type of cooling: Cooled by natural convection
Derating > 1km: 5%/1km
Derating > 45 °C: 2.5%/K
Ambient temperature without derating: -10 to +45 C°
PE connection - dimension: 6.3 x 0.8
PE connection - type: 2 x faston terminal
Mains connection - tightening torque: 0.5-1.0 Nm
Mains connection - dimension: 4 mm2
Mains connection - type: Screw terminal
L tolerance: ±10%
Winding resistance: 45 mOhm
Inductance L: 1050 uH
Rated current,,7 A
Rated frequency: 50-60 Hz
Rated voltage:,,380-500 V
Specifications:,,

MCC 103 line reactor is specially designed to match the Danfoss

VLT® Line reactor MCC 103 - line reactor for load sharing

MCC103A72K0T5L1020E00TB

frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive in applications using load sharing. Use the MCC 103 line reactor for up to 500V mains supply with 50 Hz or 60 Hz mains frequency. The MCC 103 line reactor is available with IP00 enclosure protection.
Mounting,,: Vertical or horizontal
Enclosure degree: IP00
Dimensions - HxWxD: 195x155 x110 mm
Weight: 5.95 kg
Operating conditions: Permanent operation with 100% load
Type of cooling: Cooled by natural convection
Derating > 1km: 5%/1km
Derating > 45 °C: 2.5%/K
Ambient temperature without derating: -10 to +45 C°
PE connection - dimension: M5x10
PE connection - type: Screw connection
Mains connection - tightening torque: 4.0-5.0 Nm
Mains connection - dimension: 35 mm2
Mains connection - type: Screw terminal
L tolerance: ±10%
Winding resistance: 2.6 mOhm
Inductance L: 102 uH
Rated current,,72 A
Rated frequency: 50-60 Hz
Rated voltage:,,380-500 V
Specifications:,,

MCC 103 line reactor is specially designed to match the Danfoss

VLT® Line reactor MCC 103 - line reactor for load sharing

MCC103A60K0T5L1230E00TB

frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive in applications using load sharing. Use the MCC 103 line reactor for up to 500V mains supply with 50 Hz or 60 Hz mains frequency. The MCC 103 line reactor is available with IP00 enclosure protection.
Mounting,,: Vertical or horizontal
Enclosure degree: IP00
Dimensions - HxWxD: 195x155 x102 mm
Weight: 4.43 kg
Operating conditions: Permanent operation with 100% load
Type of cooling: Cooled by natural convection
Derating > 1km: 5%/1km
Derating > 45 °C: 2.5%/K
Ambient temperature without derating: -10 to +45 C°
PE connection - dimension: M5x10
PE connection - type: Screw connection
Mains connection - tightening torque: 4.0-5.0 Nm
Mains connection - dimension: 35 mm2
Mains connection - type: Screw terminal
L tolerance: ±10%
Winding resistance: 2.7 mOhm
Inductance L: 123 uH
Rated current,,60 A
Rated frequency: 50-60 Hz
Rated voltage:,,380-500 V
Specifications:,,

MCC 103 line reactor is specially designed to match the Danfoss

VLT® Line reactor MCC 103 - line reactor for load sharing

Ver: