AHF-DA-133-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters "VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF010 connected in front of the Danfoss VLT® the harmonic current" distortion generated back to the mains is reduced to maximum 10% at full load.
Accessories:
IP21 / NEMA 1 Kit: 130B3278
IP21 / NEMA 1 Kit with capacitor disconnect: 130B5907
Back plate: 130B3287
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 133A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X5

AHF-DA-171-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters "VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF010 connected in front of the Danfoss VLT® the harmonic current" distortion generated back to the mains is reduced to maximum 10% at full load.
Accessories:
IP21 / NEMA 1 Kit: 130B3279
IP21 / NEMA 1 Kit with capacitor disconnect: 130B5908
Back plate: 130B3287
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 171A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X6

AHF-DA-204-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters "VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF010 connected in front of the Danfoss VLT® the harmonic current" distortion generated back to the mains is reduced to maximum 10% at full load.
Accessories:
IP21 / NEMA 1 Kit: 130B3279
IP21 / NEMA 1 Kit with capacitor disconnect: 130B5908
Back plate: 130B3287
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 204A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X6

AHF-DA-251-400-50-20-A

designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF 010 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 10% at full load. secured separately during installation.
Enclosure: X7
Ambient temperature without derating: 5-45 ºC
Efficiency: > 98%
Cooling concept: Forced cooled by build-in fan
Enclosure rating: 20
Overload capacity: 160% for 60 sec. every 10 min.
Line frequency tolerances: +5% / -1.5%
Line voltage tolerances: +/- 10%
Filter current: 251A
Line frequency: 50Hz
Line voltage: 380-415V
THiD less than 10%
Specifications:
Type 1/NEMA conversion kit with capacitor disconnect: 175U5909
IP20 to Type 1/NEMA conversion kit: 175U3281
Accessories:
[!]Forced cooling is not included within IP00 types. Cooling must be
The VLT® Advanced Harmonic Filter is a passive harmonic filter specially

AHF-DA-304-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters "VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF010 connected in front of the Danfoss VLT® the harmonic current" distortion generated back to the mains is reduced to maximum 10% at full load.
Accessories:
IP21 / NEMA 1 Kit: 130B3281
IP21 / NEMA 1 Kit with capacitor disconnect: 130B5909
Back plate: 130B3288
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 304A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X7

Ver: