VLT® Advanced Harmonic Filter AHF 005/AHF 010

Se muestra(n) 185 producto(s)

AHF-DA-010-400-50-20-A

The Danfoss Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive frequency converters. With AHF 010 connected in front of the Danfoss VLT®, the harmonic current distortion generated back to the mains is reduced to 0.1 total harmonic current distortion at full load.
Accessories:
NEMA 1/IP21 upgrade kit for IP20 units: IP21 / NEMA 1 Kit for AHF X1 enclosure - 130B3274
NEMA 1/IP21 upgrade kit for IP20 units with capacitor disconnect: IP21 / NEMA 1 Kit for AHF X1 enclosure and contactor CI 9 - 130B5903
Back plate: Back plate for X1 - 130B3283

AHF-DA-014-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF 010 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 10% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3274
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5903
Back plate: 130B3283
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 014A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X1

AHF-DA-022-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF 010 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 10% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3275
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5904
Back plate: 130B3284
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 022A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X2

AHF-DA-029-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfo
Enclosure: X2
Ambient temperature without derating: 5-45 ºC
Efficiency: > 98%
Cooling concept: Forced cooled by build-in fan
Enclosure rating: 20
Overload capacity: 160% for 60 sec. every 10 min.
Line frequency tolerances: +5% / -1.5%
Line voltage tolerances: +/- 10%
Filter current: 029A
Line frequency: 50Hz
Line voltage: 380-415V
THiD less than 10%
Specifications:
Back plate: 130B3284
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5904
IP20 to Type 1/NEMA conversion kit: 130B3275
Accessories:uring installation.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately dduced to maximum 10% at full load.ected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is ress frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF 010 conn

AHF-DA-034-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF 010 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 10% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3276
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5905
Back plate: 130B3285
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 034A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X3

AHF-DA-040-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF 010 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 10% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3276
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5905
Back plate: 130B3285
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 040A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X3

AHF-DA-055-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF 010 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 10% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3276
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5905
Back plate: 130B3285
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 055A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X3

AHF-DA-066-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF 010 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 10% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3277
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5906
Back plate: 130B3286
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 066A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X4

AHF-DA-082-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters "VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF010 connected in front of the Danfoss VLT® the harmonic current" distortion generated back to the mains is reduced to maximum 10% at full load.
Accessories:
IP21 / NEMA 1 Kit: 130B3277
IP21 / NEMA 1 Kit with capacitor disconnect: 130B5906
Back plate: 130B3286
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 082A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X4

AHF-DA-096-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters "VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF010 connected in front of the Danfoss VLT® the harmonic current" distortion generated back to the mains is reduced to maximum 10% at full load.
Accessories:
IP21 / NEMA 1 Kit: 130B3278
IP21 / NEMA 1 Kit with capacitor disconnect: 130B5907
Back plate: 130B3287
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 096A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X5

AHF-DA-133-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters "VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF010 connected in front of the Danfoss VLT® the harmonic current" distortion generated back to the mains is reduced to maximum 10% at full load.
Accessories:
IP21 / NEMA 1 Kit: 130B3278
IP21 / NEMA 1 Kit with capacitor disconnect: 130B5907
Back plate: 130B3287
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 133A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X5

AHF-DA-171-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters "VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF010 connected in front of the Danfoss VLT® the harmonic current" distortion generated back to the mains is reduced to maximum 10% at full load.
Accessories:
IP21 / NEMA 1 Kit: 130B3279
IP21 / NEMA 1 Kit with capacitor disconnect: 130B5908
Back plate: 130B3287
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 171A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X6

AHF-DA-204-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters "VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF010 connected in front of the Danfoss VLT® the harmonic current" distortion generated back to the mains is reduced to maximum 10% at full load.
Accessories:
IP21 / NEMA 1 Kit: 130B3279
IP21 / NEMA 1 Kit with capacitor disconnect: 130B5908
Back plate: 130B3287
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 204A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X6

AHF-DA-251-400-50-20-A

designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF 010 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 10% at full load. secured separately during installation.
Enclosure: X7
Ambient temperature without derating: 5-45 ºC
Efficiency: > 98%
Cooling concept: Forced cooled by build-in fan
Enclosure rating: 20
Overload capacity: 160% for 60 sec. every 10 min.
Line frequency tolerances: +5% / -1.5%
Line voltage tolerances: +/- 10%
Filter current: 251A
Line frequency: 50Hz
Line voltage: 380-415V
THiD less than 10%
Specifications:
Type 1/NEMA conversion kit with capacitor disconnect: 175U5909
IP20 to Type 1/NEMA conversion kit: 175U3281
Accessories:
[!]Forced cooling is not included within IP00 types. Cooling must be
The VLT® Advanced Harmonic Filter is a passive harmonic filter specially

AHF-DA-304-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters "VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF010 connected in front of the Danfoss VLT® the harmonic current" distortion generated back to the mains is reduced to maximum 10% at full load.
Accessories:
IP21 / NEMA 1 Kit: 130B3281
IP21 / NEMA 1 Kit with capacitor disconnect: 130B5909
Back plate: 130B3288
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 304A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X7

AHF-DA-381-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters "VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF010 connected in front of the Danfoss VLT® the harmonic current" distortion generated back to the mains is reduced to maximum 10% at full load.
Accessories:
IP21 / NEMA 1 Kit: 130B3281
IP21 / NEMA 1 Kit with capacitor disconnect: 130B5909
Back plate: 130B3288
Specifications:
THiD less than 10%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 381A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X7

AHF-DA-480-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfo
Enclosure: X8
Ambient temperature without derating: 5-45 ºC
Efficiency: > 98%
Cooling concept: Forced cooled by build-in fan
Enclosure rating: 20
Overload capacity: 160% for 60 sec. every 10 min.
Line frequency tolerances: +5% / -1.5%
Line voltage tolerances: +/- 10%
Filter current: 480A
Line frequency: 50Hz
Line voltage: 380-415V
THiD less than 10%
Specifications:
Back plate: 130B3288
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B6101
IP20 to Type 1/NEMA conversion kit: 130B3282
Accessories:uring installation.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately dduced to maximum 10% at full load.ected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is ress frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF 010 conn

AHF-DB-010-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3274
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5903
Back plate: 130B3283
Specifications:
THiD less than 5%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 010A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Cooled by natural convection
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X1

AHF-DB-014-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfo
Enclosure: X1
Ambient temperature without derating: 5-45 ºC
Efficiency: > 98%
Cooling concept: Forced cooled by build-in fan
Enclosure rating: 20
Overload capacity: 160% for 60 sec. every 10 min.
Line frequency tolerances: +5% / -1.5%
Line voltage tolerances: +/- 10%
Filter current: 014A
Line frequency: 50Hz
Line voltage: 380-415V
THiD less than 5%
Specifications:
Back plate: 130B3283
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5903
IP20 to Type 1/NEMA conversion kit: 130B3274
Accessories:uring installation.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately duced to maximum 5% at full load.cted in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is redss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 conne

AHF-DB-022-400-50-20-A

The VLT® Advanced Harmonic Filter is a passive harmonic filter specially designed to match the Danfoss frequency converters VLT® AutomationDrive, VLT® AQUA Drive and VLT® HVAC Drive. With AHF005 connected in front of the Danfoss VLT® the harmonic current distortion generated back to the mains is reduced to maximum 5% at full load.
[!]Forced cooling is not included within IP00 types. Cooling must be secured separately during installation.
Accessories:
IP20 to Type 1/NEMA conversion kit: 130B3275
IP20 to Type 1/NEMA conversion kit with capacitor disconnect: 130B5904
Back plate: 130B3284
Specifications:
THiD less than 5%
Line voltage: 380-415V
Line frequency: 50Hz
Filter current: 022A
Line voltage tolerances: +/- 10%
Line frequency tolerances: +5% / -1.5%
Overload capacity: 160% for 60 sec. every 10 min.
Enclosure rating: 20
Cooling concept: Forced cooled by build-in fan
Efficiency: > 98%
Ambient temperature without derating: 5-45 ºC
Enclosure: X2

Ver: