![Energy meters, Infocal 9, 40 mm - 100 mm, qp [m³/h]: 10.0 - 60.0, Heating and cooling, battery D-cell, M-bus module Energy meters, Infocal 9, 40 mm - 100 mm, qp [m³/h]: 10.0 - 60.0, Heating and cooling, battery D-cell, M-bus module](https://assets.danfoss.com/photos/preview/144831/ID251733583799-0101_preview.jpg?w=96&h=96)
Energy meters, Infocal 9, 40 mm - 100 mm, qp [m³/h]: 10.0 - 60.0, Heating and cooling, battery D-cell, M-bus module
187F9001
Energy calculator
Energy calculator
Gross weight | 0.7 kg |
Net weight | 0.7 kg |
EAN | 5702428985680 |
Gross weight | 0.7 kg |
Net weight | 0.7 kg |
EAN | 5702428985680 |
Accuracy standard | Class 2 to EN1434 |
Ambient class | E2/M1 |
Ambient humidity [% RH] [Max] | 93 % RH |
Ambient temperature [°C] [Max] | 55 °C |
Ambient temperature [°C] [Min] | 5 °C |
Application | Heating and cooling |
Approval authority | MID |
Battery lifetime [Years] | 12 yr |
Description | Energy calculator |
Diameter [mm] [Max] | 100 mm |
Diameter [mm] [Min] | 40 mm |
Display type | LCD |
Energy unit | MWh |
For flow meter | SonoSensor 30 |
Installation | Return |
Integrated communication | 2 pulse input |
Interface module slot 1 | M-bus module |
IP protection class | IP 65 |
Log storage duration [Month] | 36 mo |
Media temperature [°C] [Max] | 160 °C |
Media temperature [°C] [Min] | 0 °C |
Product group | Energy meters |
Pulse value volume [l/pulse] | 10 l/pulse |
qp [m³/h] [Max] | 60 m³/h |
qp [m³/h] [Min] | 10 m³/h |
Supply voltage [V] DC | 3.6 V |
Supply voltage type | battery D-cell |
Temperature sensor diameter [mm] | 5.2 mm |
Temperature sensor length [mm] | 3 m |
Temperature sensors type | Pt 500 |
Type | Infocal 9 |
Accuracy standard | Class 2 to EN1434 |
Ambient class | E2/M1 |
Ambient humidity [% RH] [Max] | 93 % RH |
Ambient temperature [°C] [Max] | 55 °C |
Ambient temperature [°C] [Min] | 5 °C |
Application | Heating and cooling |
Approval authority | MID |
Battery lifetime [Years] | 12 yr |
Description | Energy calculator |
Diameter [mm] [Max] | 100 mm |
Diameter [mm] [Min] | 40 mm |
Display type | LCD |
Energy unit | MWh |
For flow meter | SonoSensor 30 |
Installation | Return |
Integrated communication | 2 pulse input |
Interface module slot 1 | M-bus module |
IP protection class | IP 65 |
Log storage duration [Month] | 36 mo |
Media temperature [°C] [Max] | 160 °C |
Media temperature [°C] [Min] | 0 °C |
Product group | Energy meters |
Pulse value volume [l/pulse] | 10 l/pulse |
qp [m³/h] [Max] | 60 m³/h |
qp [m³/h] [Min] | 10 m³/h |
Supply voltage [V] DC | 3.6 V |
Supply voltage type | battery D-cell |
Temperature sensor diameter [mm] | 5.2 mm |
Temperature sensor length [mm] | 3 m |
Temperature sensors type | Pt 500 |
Type | Infocal 9 |