AFD 2, PN 40, 3.00 bar - 8.50 bar, 80 cm²
003G5624
VVS: 406478624
Pressure reduction actuator
Pressure reduction actuator
Gross weight | 12.566 Kilogram |
Net weight | 9.67 Kilogram |
Volume | 68.517 Liter |
EAN | 5715162001479 |
Gross weight | 12.566 Kilogram |
Net weight | 9.67 Kilogram |
Volume | 68.517 Liter |
EAN | 5715162001479 |
Actuator diaphragm material | EPDM (Rolling, fibre enforced) |
Actuator size [cm²] | 80 cm² |
Application | District heating and cooling |
Body material | Steel, mat. No. 1.0345, zinc plated |
China RoHS compliance | Out of scope |
Description | Pressure reduction actuator |
Diameter [mm] [Max] | 125 mm |
Diameter [mm] [Min] | 65 mm |
Differential pressure setting [bar] [Max] | 8.5 bar |
Differential pressure setting [bar] [Min] | 3 bar |
EU RoHS compliance | Out of scope |
Flow control | No |
Flow limitation | No |
Function | Press. reduction controller |
In scope of WEEE and contain batteries | No |
Media pH [Max] | 10 |
Media temperature [°C] [Max] | 150 °C |
Media temperature [°C] [Min] | 2 °C |
Medium alternative | Glycolic water up to 30% |
Mounting version | Flow |
Operating pressure [bar] [Max] | 40 bar |
Permissible media | District heating/cooling circulation water |
Pressure class | PN 40 |
Pressure controller | Press. reduction controller |
Pressure nominal [bar] | 40 bar |
Pressure setting range [bar] [Max] | 8.5 bar |
Pressure setting range [bar] [Min] | 3 bar |
Product group | Actuators - Pressure Flow |
Select if the Shock valve should be with a Fixed pressure or Adjustablepressure | Adjustable |
Type | AFD 2 |
UK RoHS compliance | Out of scope |
Actuator diaphragm material | EPDM (Rolling, fibre enforced) |
Actuator size [cm²] | 80 cm² |
Application | District heating and cooling |
Body material | Steel, mat. No. 1.0345, zinc plated |
China RoHS compliance | Out of scope |
Description | Pressure reduction actuator |
Diameter [mm] [Max] | 125 mm |
Diameter [mm] [Min] | 65 mm |
Differential pressure setting [bar] [Max] | 8.5 bar |
Differential pressure setting [bar] [Min] | 3 bar |
EU RoHS compliance | Out of scope |
Flow control | No |
Flow limitation | No |
Function | Press. reduction controller |
In scope of WEEE and contain batteries | No |
Media pH [Max] | 10 |
Media temperature [°C] [Max] | 150 °C |
Media temperature [°C] [Min] | 2 °C |
Medium alternative | Glycolic water up to 30% |
Mounting version | Flow |
Operating pressure [bar] [Max] | 40 bar |
Permissible media | District heating/cooling circulation water |
Pressure class | PN 40 |
Pressure controller | Press. reduction controller |
Pressure nominal [bar] | 40 bar |
Pressure setting range [bar] [Max] | 8.5 bar |
Pressure setting range [bar] [Min] | 3 bar |
Product group | Actuators - Pressure Flow |
Select if the Shock valve should be with a Fixed pressure or Adjustablepressure | Adjustable |
Type | AFD 2 |
UK RoHS compliance | Out of scope |