VLT® Refrigeration Drive FC 103

Viser 230 produkt (er)

132X0694

FC-103N132T4E5MH4XGC3XXSXXXXAXBKCXXXXDX

Frekvensomformere
FC-103N132T4E5MH4XGC3XXSXXXXAXBKCXXXXDX
VLT® Refrigeration Drive FC-103
132 KW / 200 HP, Trefaset
380 - 480 VAC, IP54 / m. terminalafskærm.
EMC filter klasse C2
Uden bremsechopper
Grafisk betjeningspanel (std)
Ekstra lakering 3C3, Indgangsafbryder og sikringer
Seneste SW version
Ingen fieldbus option, MCB 101 General purpose I/O
Ingen C1 option, Ingen ekst. 24V DC klemmer
Kapsling: D5H (H1324 B325 D381)
Andre muligheder i henhold til Model Code

Typekode: FC-103N132T4E5MH4XGC3XXSXXXXAXBKCXXXXDX

132X7001

FC-103N110T4E5MH2XGC3XXSXXXXAXBXCXXXXDX

Frekvensomformere
FC-103N110T4E5MH2XGC3XXSXXXXAXBXCXXXXDX
VLT® Refrigeration Drive FC-103
110 KW / 150 HP, Trefaset
380 - 480 VAC, IP54 / m. terminalafskærm.
EMC filter klasse C3 (Se info)
Uden bremsechopper
Grafisk betjeningspanel (std)
Ekstra lakering 3C3, Indgangsafbryder og sikringer
Seneste SW version
Ingen fieldbus option, Ingen I/O option
Ingen C1 option, Ingen ekst. 24V DC klemmer
Kapsling: D5H (H1324 B325 D381)
Andre muligheder i henhold til Model Code

Typekode: FC-103N110T4E5MH2XGC3XXSXXXXAXBXCXXXXDX

132X9846

FC-103P55KT4E20H1TGXXXXSXXXXAXBKCXXXXD0

Frekvensomformere
FC-103P55KT4E20H1TGXXXXSXXXXAXBKCXXXXD0
VLT® Refrigeration Drive FC-103
55 KW, Trefaset
380 - 480 VAC, IP20
EMC filter klasse C2/C1 (Std.)
Sikker standsning STO
Grafisk betjeningspanel (std)
Standard lakering 3C2, Uden forsyningsnet option
Seneste SW version
Ingen fieldbus option, MCB 101 General purpose I/O
Ingen C1 option, MCB 107 24V DC backup
Kapsling: C3 (H550 B308 D333)
Andre muligheder i henhold til Model Code

Typekode: FC-103P55KT4E20H1TGXXXXSXXXXAXBKCXXXXD0

134F7345

FC-103P1K1T2E20H1TGXXXXSXXXXAZBXCXXXXDX

Frekvensomformere
FC-103P1K1T2E20H1TGXXXXSXXXXAZBXCXXXXDX
VLT® Refrigeration Drive FC-103
1,1 KW, Trefaset
200 - 240 VAC, IP20
EMC filter klasse C2/C1 (Std.)
Sikker standsning STO
Grafisk betjeningspanel (std)
Standard lakering 3C2, Uden forsyningsnet option
Seneste SW version
MCA 107 AKD-LonWorks, Ingen I/O option
Ingen C1 option, Ingen ekst. 24V DC klemmer
Kapsling: A2 (H268 B90 D205)
Andre muligheder i henhold til Model Code

Typekode: FC-103P1K1T2E20H1TGXXXXSXXXXAZBXCXXXXDX

134F7348

FC-103P75KT4E55H1TGXXXXSXXXXAXBXCXXXXDX

Frekvensomformere
FC-103P75KT4E55H1TGXXXXSXXXXAXBXCXXXXDX
VLT® Refrigeration Drive FC-103
75 KW, Trefaset
380 - 480 VAC, IP55
EMC filter klasse C2/C1 (Std.)
Sikker standsning STO
Grafisk betjeningspanel (std)
Standard lakering 3C2, Uden forsyningsnet option
Seneste SW version
Ingen fieldbus option, Ingen I/O option
Ingen C1 option, Ingen ekst. 24V DC klemmer
Kapsling: C2 (H770 B370 D335)
Andre muligheder i henhold til Model Code

Typekode: FC-103P75KT4E55H1TGXXXXSXXXXAXBXCXXXXDX

Vis: