Accessories FC 301/302

Shows 248 product(s)

130B1245

VLT® PROFIBUS Converter MCA 113, ctd

Ensures easy and quick replacement of VLT®3000 to VLT® AutomationDrive
.
VLT® 3000 can then be replaced by VLT® AutomationDrive or
- the system Can be expanded without costly changes to the PLC program
- Flexible investment as it is easy to remove and replace option when upgrading
to another fieldbus
Product group: R1

130B1246

VLT® PROFIBUS Converter MCA 114, ctd

A special version of the PROFIBUS options that emulates VLT® 5000
commands in the VLT® AutomationDrive. The VLT® 5000 can be replaced by
the VLT® AutomationDrive, or an existing system can be expanded without
costly change of the PLC program. For upgrade to a different fieldbus,
the installed converter is easily removed and replaced with a new
option. This secures the investment without losing flexibility. The
option supports DPV1.

130B1252

VLT® Synchronizing Ctrl. MCO 350, ctd

MCO 350 - synchronous controller
Based on the MCO 305 prefabricated controller for Synchronization tasks. The adjustment
takes place through parameter settings. Specific Programming skills are not required.
- 2 encoder inputs, both for incremental as well as absolute encoder
- 1 encoder output (virtual master function)
- 10 additional digital inputs
- 8 additional digital outputs
- fieldbus Communication (requires fieldbus card) with reinforced coating

130B1253

VLT® Position Controller MCO 351, ctd

Extends the functional characteristics of the frequency converter in positioning
applications
- Direct positioning via fieldbus, relative positioning, absolute positioning and
touch probe positioning
- End stop handling (software and hardware)
- Mechanical brake handling (programmable hold delay)
Error handling
- Jog speed / manual operation
- None for programming, as it is pre-programmed
Remember to order the Mounting kit if the above MCO option is required
retrofitted.
130B7530 - Mounting kit for enclosures A2 and A3
130B7531 - Mounting kit for MCO Option,
together with MCB 113, in enclosures A2 and A3
130B1413 - Mounting kit for enclosure B3
130B1414 - Mounting kit for MCO Option,
together with MCB 113, in enclosure B3
130B7532 - Mounting kit for enclosure A5
130B7533 - Mounting kit for all enclosures B, C, D, E and F (B3
excepted)
Danfoss MCO options are not sold without prior advice.
Danfoss can offer help with programming / setting up MCO options.
Contact Danfoss for advice and prices.
Product group: R

130B1264

VLT® Extended Relay Card MCB 113, ctd

Adds 7 digital inputs and 2 analog outputs for increased flexibility. 4
SPDT relays. Meets NAMUR recommendations. Galvanic isolation capability.

130B1272

VLT® Sensor Input Card MCB 114, coated

MCB 114 - PT100 / PT1000 option
For FC100-FC200 and FC302 (painted version)
Enables the evaluation of up to 3 PT 100 or 3 PT 1000 sensors
- Connection of 2 and 3 wire sensors
- Automatic detection of the sensor type
- Additional 4-20mA input

130B1296

VLT® Modbus TCP MCA 122, coated

The first industrial Ethernet-based protocol for automation. Connects to
Modbus-TCP-based networks. Able to handle connection interval down to 5
ms in both directions, positioning it among the fastest performing
Modbus TCP devices in the market. For master redundancy it features hot
swapping between two masters.

130B1490

VLT® POWERLINK MCA 123, coated

Represents the second generation of fieldbus. The high bit rate of
industrial Ethernet can now be used to make the full power of IT
technologies used in the automation world available for the factory
world.

130B3150

Back plate for enclosure A4

FC 300 rear cover (galvanized steel) IP55 / NEMA 12 Case size: A4

130B3242

Back plate IP66/Type 4X, A5

FC 300 rear cover (stainless steel) for the devices in IP66 Case size A5

130B3280

VLT® Safe option MCB 150, coated

Safety modules enable machines to interact intelligently with operators to increase safety, reduce system costs, improve flexibility and increase productivity.

VLT® MCB 15x Safe options provide an intelligent, user-friendly solution to meet the IEC 61800-5-2 functional safety standard and helps to reduce cabling.

The new safety module is certified according to ISO 13849-1 PL d Category 3 and SIL 2 according to IEC 61508.

130B3290

VLT® Safe option MCB 151, coated

VLT® Safe option MCB 151, painted for HTL feedback, can
be used up to PL d or SIL 2

View: